An analysis is presented of inductively-loaded single-phase and three-phase thyristor bridge rectifier circuits, in which the source impedance cannot be neglected. It is shown that, as the ratio of the source reactance to the load resistance is raised, modes of operation with differing characteristics occur. Although the effect of an increased delay in the thyristor firing signals is normally to reduce the output voltage, it is shown that under certain conditions no change whatsoever is produced in the circuit wave-forms.
Get full access to this article
View all access options for this article.
References
1.
HegemeierH.‘Compounded synchronous generators rated from 0.5 to 4,000 kVA’Brown Boveri Review, 54, pp. 568–572 (1967).
GilchristD. C.‘Self excitation of alternators by static exciters’GEC Journal, 28, 5–13 (1960).
4.
DavisR. M.‘Circuits using diodes and thyristors’, Presented at the conference on Electrical Power and Machines in Applications on Railways, University of Nottingham, (April 1967).
5.
HoeltersF.‘Current and voltage conditions from no load to short circuit in three-phase bridge circuit’, Direct Current, 5, 112–117 (1960).
6.
SchaeferJ.Rectifier circuits, theory and design, Wiley (1965).
7.
SmithI. R. and NisarP. A.‘Bridge-rectifier operation with a constant-current source’, Int. J. Elect. Enging Educ., 10, 15–19 and 75–79 (1972).
8.
SmithI. R. and NisarP. A.‘Bridge-rectifier operation with a high-impedance source’, Int. J. Elect. Enging Educ., 11, 118–132 (1974).
9.
FrerisL. L.‘Analysis of a Hybrid Bridge Rectifier’, Direct Current, 1, 22–33 (1966).
10.
KimbarkE. M.Direct Current Transmission, Vol. 1, Wiley (1971).