The Uniform Determination of Death Act and the American Academy of Neurology's Guidelines for Determination of Death define procedures for diagnosis of brain death before organ procurement for transplantation, including clinical assessment and apnea test. Autotriggering of mechanical ventilators can occur in both brain dead and living patients. A case is reported in which procurement was delayed because ventilator self-cycling was confused for brainstem-mediated respiratory effort. Background knowledge to effectively troubleshoot ventilator self-cycling is offered so that unnecessary delays in brain death testing can be avoided.
Guidelines for the determination of death.Report of the medical consultants on the diagnosis of death to the President's Commission for the Study of Ethical Problems in Medicine and Biomedical and Behavioral Research. JAMA.1981;246(19): 2184–2186.
3.
WijdicksEFMVarelasPNGronsethGSGreerDM; American Academy of Neurology. Evidence-based guideline update: Determining brain death in adults: Report of the Quality Standards Subcommittee of the American Academy of Neurology. Neurology.2010;74(23):1911–1918.
4.
WijdicksEF. Determining brain death in adults. Neurology.1995;45(5):1003–1011.
5.
AraulloMLFrankJIGoldenbergFDRosengartAJ. Transient bilateral finger tremor after brain death. Neurology.2007;68(16):E22.
6.
JungKYHanSGLeeKHChungCS. Repetitive leg movements mimicking periodic leg movement during sleep in a brain-dead patient. Eur J Neurol.2006;13(7):e3–e4.
7.
ZubkovAYWijdicksEF. Plantar flexion and flexion synergy in brain death. Neurology.2008;70(19):e74.
8.
WillattsSMDrummondG. Brainstem death and ventilator trigger settings. Anaesthesia.2000;55(7):676–677.
9.
ArbourR. Cardiogenic oscillation and ventilator autotriggering in brain-dead patients: A case series. Am J Crit Care.2009;18(5):496, 488–495.
10.
WijdicksEFMMannoEMHoletsSR. Ventilator self-cycling may falsely suggest patient effort during brain death determination. Neurology.2005;65(5):774.
11.
ColeRP. Cardiogenic oscillations and apparent ventilation in suspected brain death. Resuscitation.2003;56(3):335.
12.
BohatyrewiczRWaleckaABohatyrewiczA. Unusual movements, “spontaneous” breathing, and unclear cerebral vessels sonography in a brain-dead patient: A case report. Transplant Proc. Nov 2007;39(9):2707–2708.
13.
KondiliEXirouchakiNGeorgopoulosD. Modulation and treatment of patient-ventilator dyssynchrony. Curr Opin Crit Care.2007;13(1):84–89.
14.
GeorgopoulosDPrinianakisGKondiliE. Bedside waveforms interpretation as a tool to identify patient-ventilator asynchronies. Intensive Care Med.2006;32(1):34–47.
15.
MurataSYokoyamaKSakamotoY. Effects of inspiratory rise time on triggering work load during pressure-support ventilation: A lung model study. Respir Care.2010;55(7):878–884.
16.
SheikhEMaguireDPGratchD. Autotriggering during pressure support ventilation due to cardiogenic oscillations. Anesth Analg.2009;109(2):470–472.
17.
HillLLPearlRG. Flow triggering, pressure triggering, and autotriggering during mechanical ventilation. Crit Care Med.2000;28(2):579–581.
18.
SpahijaJDe MarchieMAlbertM. Patient-ventilator interaction during pressure support ventilation and neurally adjusted ventilatory assist. Crit Care Med.2010;38(2):518–526.
19.
ImanakaHNishimuraMTakeuchiMKimballWRYahagiNKumonK. Autotriggering caused by cardiogenic oscillation during flow-triggered mechanical ventilation. Crit Care Med.2000;28(2):402–407.
20.
HoltTB. Cardiogenic triggering observed in a patient with acute respiratory distress syndrome. Respir Care.2001;46(10): 1054–1055.
21.
AudibertGCharpentierCSeguin-DevauxC. Improvement of donor myocardial function after treatment of autonomic storm during brain death. Transplantation.2006;82(8):1031–1036.
22.
WoodKEBeckerBNMcCartneyJGD'AlessandroAMCoursinDB. Care of the potential organ donor. N Engl J Med.2004;351(26):2730–2739.