BransonRD, ChatburnRL. Humidification of inspired gases during mechanical ventilation (editorial). Respir Care1993;38:461–468.
2.
McCombRC, RhameFS, StriefelA, BoyleMJ. Bubbling humidifiers produce microaerosols which can carry bacteria. Infect Control1989;7:403–409.
3.
CravenDE, GoularteTA, MakeBJ. Contaminated condensate in mechanical ventilator circuits: a risk factor for nosocomial pneumonia?Am Rev Respir Dis1984;129:625–628.
4.
IrwinRS, DemersRR, PratterMR, GarrityFL, MinerG, PritchardA.An outbreak of Acinetobacter infection associated with the use of a ventilator spirometer. Respir Care1980;25:232–237.
5.
Malecka-GriggsB, ReinhardtDJ. Direct dilution sampling, quantitation, and microbial assessment of open-system ventilation circuits in intensive care units. J Clin Microbiol1983;17:870–877.
6.
CredleWFJr, SmiddyJF, ElliottRC. Complications of fiberoptic bronchoscopy. Am Rev Respir Dis1974;109:67–72.
7.
LeFrockJL, KlainerAS, WuWH, TurndorfH.Transient bacteremia associated with nasotracheal suc-tioning. JAMA1976;236:1610–1611.
8.
PereiraW, KovnatDM, KhanMA, IacovinoJR, SpivackML, SniderGL. Fever and pneumonia after flexible fiberoptic bronchoscopy. Am Rev Respir Dis1975;112:59–64.
9.
BryantLR, TrinkleJK, Mobin-UddinK, BakerJ, GriffenWOJr. Bacterial colonization profile with tracheal intubation and mechanical ventilation. Arch Surg1972;104:647–651.
10.
CravenDE, LichtenbergDA, GoularteTA, MakeBJ, McCabeWR. Contaminated medication nebulizers in mechanical ventilator cir-cuits: source of bacterial aerosols. Am J Med1984;77:834–838.
11.
HedleyRM, Allt-GrahamJ.A com-parison of the filtration properties of heat and moisture exchangers. Anaesthesia1992;47:414–420.
12.
MalaskyC, JordanT, PotulskiF, ReichmanLB. Occupational tuberculous infections among pulmo-nary physicians in training. Am Rev Respir Dis1990;142:505–507.
13.
PownerDJ, SandersCS, BaileyBJ. Bacteriologic evaluation of the Servo 150 hygroscopic condenser-humidifier. Crit Care Med1986;14:135–137.
14.
DemersRR, ParkerJ, FrankelLR, SmithDW. Administration of riba-virin to neonatal and pediatric pa-tients during mechanical ventila-tion. Respir Care1986;31:1188–1196.
15.
DemersRR. Update: ribavirin ad-ministration during mechanical ven-tilation. Can J Respir Ther1991;27(3):9–14.
16.
GallagherJ, StrangewaysJEM, Allt-GrahamJ.Contamination con-trol in long-term ventilation: a clin-ical study using a heat-and moisture exchange filter. Anaesthesia1987;42:476–481.
17.
WilleB.Hygiene measures for an-esthesia and ventilator equipment. Krankenhaus-Hygiene+Infections-verhutung1989;11:1721.
18.
LeeMG, FordJL, HuntPB, IrelandDS, SwansonPW. Bacterial reten-tion properties of heat and moisture exchange filters. Br J Anaesth1992;69:522–525.
19.
DemersRR. Humidification sys-tems. In: KacmarekRM, StollerJK, eds. Current respiratory care tech-niques and therapy. Toronto: BC Decker Inc, 1988.
20.
MissettB, EscudierB, RivaraD, LeclercqB, NitenbergG. (Com-munication to the Editor.) Chest1992;102:979–980.
21.
CohenIL, WeinbergPF, FeinIA, RowiniskiGS. Endotracheal tube occlusion associated with the use of heat and moisture exchangers in the intensive care unit. Crit Care Med1988;16:277–279.
22.
DemersRR. Endotracheal tube oc-clusion associated with the use of heat and moisture exchanges in the intensive care unit (letter). Crit Care Med1989;17:845–846.
23.
RoustanJP, KienlenJ, AubasP, AubasS, du CailarJ.Comparison of hydrophobic heat and moisture exchangers with heated humidifier during prolonged mechanical ven-tilation. Intensive Care Med1992;18:97–100.
24.
MartinC, PerrinG, GevaudanMJ, SauxP, GouinF.Heat and moisture exchangers and vaporizing humid-ifiers in the intensive care unit. Chest1990;97:144–149.
25.
MissetB, EscudierB, RivaraD, LeclercqB, NitenbergG.Heat and moisture exchanger vs heated humidifier during long-term me-chanical ventilation: a prospective randomized study. Chest1991;100:160–163.