Editorial
Select search scope: search across all journals or within the current journal






It has been demonstrated that a spectrochemical analysis of carbon using the laser plasma method can be successfully applied to inspect the carbonation of concrete by detecting carbon produced in aged concrete by a chemical reaction of Ca(OH)2 with CO2 gas in environmental air, turning into CaCO3, which induces degradation of the quality of building concrete. A comparative study has been made using a TEA CO2 laser (500–1000 mJ) and a Q-switched Nd– YAG laser (50–200 mJ) to search for the optimum conditions for carbon analysis, proving the advantage of the TEA CO2 laser for this purpose. Also, it was clarified that laser irradiation with suitable defocusing conditions is a crucial point for obtaining high sensitivity in the detection of carbon. Practical experiments on the inspection of carbonation were carried out using both a concrete sample that had been intentionally carbonated by exposure to high concentrations of CO2 gas and a naturally carbonated concrete sample. As a result, good coincidence was observed between the laser method and the ordinary method, which uses the chemical indicator phenolphthalein, implying that this laser technique is applicable as an
Recently, laser-induced breakdown spectroscopy (LIBS) has been developed for the elemental analysis of geological samples for application to space exploration. There is also interest in using the technique for the analysis of water ice and ice/dust mixtures located at the Mars polar regions. The application is a compact instrument for a lander or rover to the Martian poles to interrogate stratified layers of ice and dusts that contain a record of past geologic history, believed to date back several million years. Here we present results of a study of the use of LIBS for the analysis of water ice and ice/dust mixtures
This paper reports the usefulness of far-ultraviolet (FUV) absorption spectroscopy in highly sensitive quantitative and qualitative analysis of aqueous solutions. We propose a totally new idea for the utilization of FUV spectroscopy in pure water and aqueous solution analyses. We use an absorption band near 170 nm due to an
Experimental results of photoacoustic (PAS) and reflectance (RS) spectroscopies of titanium dioxide thin films (TiO2), deposited on Si substrates, are compared in a wide optical range including transparent and absorbent regions of TiO2. Due to the fact that the light modulation frequency
Novel Ag on TiO2 films are generated by semiconductor photocatalysis and characterized by ultraviolet–visible (UV/Vis) spectroscopy, scanning electron microscopy (SEM), and atomic force microscopy (AFM), as well as assessed for surface-enhanced Raman scattering (SERS) activity. The nature and thickness of the photo-deposited Ag, and thus the degree of SERS activity, is controlled by the time of exposure of the TiO2 film to UV light. All such films exhibit the optical characteristics (λmax ≅ 390 nm) of small (<20 nm) Ag particles, although this feature becomes less prominent as the film becomes thicker. The films comprise quite large (>40 nm) Ag islands that grow and merge with increasing levels of Ag photodeposition. Tested with a benzotriazole dye probe, the films are SERS active, exhibiting activity similar to that of 6-nm-thick vapor-deposited films. The Ag/TiO2 films exhibit a lower residual standard deviation (∼25%) compared with Ag vapor-deposited films (∼45%), which is, however, still unacceptable for quantitative work. The sample-to-sample variance could be reduced significantly (<7%) by spinning the film during the SERS measurement. The Ag/TiO2 films are mechanically robust and resistant to removal and damage by scratching, unlike the Ag vapor-deposited films. The Ag/TiO2 films also exhibit no obvious loss of SERS activity when stored in the dark under otherwise ambient conditions. The possible extension of this simple, effective method of producing Ag films for SERS, to metals other than Ag and to semiconductors other than TiO2, is briefly discussed.
A new application of the recently described drop coating deposition Raman (DCDR) method facilitates the segregation and independent spectral characterization of mixture components. The quality of the normal (un-enhanced) Raman spectra are significantly improved as a result of reduced spectral interference from fluorescent impurities and buffer compounds. Fluorescence of commercial amino acid (O-phospho-L-serine) and protein (myoglobin) samples is reduced by over an order of magnitude using DCDR, more effectively than prolonged photo-bleaching. Furthermore, DCDR is used to obtain high-quality Raman spectra of proteins, lysozyme, and insulin, derived from solutions with up to 1000-fold excess buffer concentration. Possible thermodynamic and kinetic contributions to the observed segregation phenomena are discussed.
Resolution of the reaction steps and the associated component Raman spectra during the formation or desorption of self-assembled monolayers is challenging because intermediate adsorbate populations are present at low concentrations and their spectral bands overlap. By collecting Raman spectra versus applied potential into a two-dimensional data set, one can utilize multivariate statistical techniques to resolve the component concentration profiles along with their corresponding Raman spectra.
Surface-enhanced Raman scattering (SERS) spectroelectrochemistry is used to characterize electrochemically roughened and highly polished polycrystalline silver SERS-active substrates. Changes in the nitrile stretching vibrational mode of adsorbed thiocyanate are used as an
Time-resolved Fourier transform infrared (FT-IR) polarization spectroscopy was employed to study the electric-field-induced reorientation of nematic
Dynamic compression modulation attenuated total reflection Fourier transform infrared (ATR FT-IR) spectroscopic methods have been developed in this paper for characterizing polymer films. To obtain dynamic compression polarized ATR spectra, internal reflection element (IRE) secure assemblies made of tungsten carbide with very high hardness (Knoop hardness of >1000 kgf/mm2) have been designed. These assemblies are mounted on the Harrick Seagull® ATR attachment and measured by step-scan FT-IR spectroscopy. The effect of static compression, air gaps, and refractive index changes were examined. Experimental and simulated results showed that the effect of air gaps between the sample and IRE and refractive index changes of the sample and IRE are negligible at values larger than a static torque of 40 cN m and good signal-to-noise ratios (SNR) and reproducible data can be obtained. Uniaxially and biaxially drawn poly(ethylene terephthalate) films were measured by the presented method. Both bipolar and unipolar bands were observed in the dynamic in-phase ATR spectra, which can be associated with their micro-structural environmental changes. This technique shows promise in evaluating various polymer film materials, including biaxially oriented films, multilayer coated film surfaces, and molecular interactions between polymer–polymer and polymer–additives at the film surface.
A new approach to modeling using semi-quantum dielectric function models is proposed for the retrieval of the optical functions from infrared spectra. The powerful points of the method are shown throughout the analysis of two semitransparent materials, MgO and KBr. All the results are discussed in light of those obtained with classical techniques. This type of model is able to retrieve, for example, the extinction index in a range that covers at least six orders of magnitude and gives access to highly valuable information about high-order phonon processes.
We present an indirect hard modeling (IHM) approach for the quantitative analysis of reactive multicomponent mixtures with intermolecular interaction. It can be used when it is not possible to obtain calibration data in the composition region of interest. The goal of this work, specifically, is to analyze reactive systems, although the validation of the method is done with nonreactive systems. Compared to conventional hard modeling, the new approach reduces the manual work required for modeling and renders unnecessary the assignment of bands in mixture spectra to individual components. It is based on parametric models of the pure component spectra that are made just flexible enough to fit the spectra of the unknown mixtures, and it only requires small calibration data sets that may lie in different regions of the composition space. The application to infrared (IR) and Raman spectra of multicomponent systems is discussed.
We describe how parametric spectral models for analytical applications can be generated by an automatic curve-fitting algorithm. The algorithm does not require initial choices of parameters or other human intervention, in contrast to established approaches that rely on deconvolution or derivative spectroscopy. This algorithm has been applied for quantitative analysis but can potentially be used in other applications that are based on parametric representations of peak-shaped models or could benefit from using such models, such as calibration transfer.
Increasingly voluminous Fourier transform infrared (FT-IR) spectroscopic imaging data sets are being generated with the advent of both faster array detectors and the implementation of time-resolved imaging techniques, resulting in data processing becoming the limiting step in visualizing sample heterogeneity and temporal profile evolution. We report the application of a Gram–Schmidt vector orthogonalization procedure in interferogram space to provide a significant time saving advantage in processing of one to two orders of magnitude in comparison to conventional spectral processing. Illustrative data from human skin biopsies and from dynamic molecular reorganizations within liquid crystalline microdomains is employed to discuss the capabilities and limitations of this information-extraction approach.
We have demonstrated that the near-infrared and infrared absorptions in the 8000–3200 cm−1 region of an OH group of 2-nonanol, 1-nonanol, etc., in n-heptane are excellently separated by subtraction without any serious interference down to very low concentrations at which OH groups are completely free. The separated sharp absorptions are assigned to the fundamental, combination, and overtone bands that are concerned with the OH stretching of free OH. Two components of a sharp overtone band around 7100 cm−1, which are observed for primary and secondary alcohols, are assigned to coexisting internal rotational isomers of an OH group around the O–C bond. The frequencies of the OH stretching fundamental and overtone bands that are assigned to internal rotational positions are consistent for all the investigated alcohols, including methanol and tertiary butanol. Comparison of the separated spectrum of 2-nonanol in n-heptane with that in 1-chlorooctane or in carbon tetrachloride makes it clear that hydrocarbon is an inert solvent that does not disturb the intrinsic nature of an alcohol OH group. There actually exists a constant anharmonicity shift of 169–175 cm−1 between the double frequency (2
The goal of this research was to develop a simple and economical fiber-optic sensor technology for agrifood process monitoring. Toward this end, two fiber-optic sensors were developed to be used in combination: a single reflection V-bend sensor and a single fiber air-gap probe. The former is designed to be sensitive toward refractive index and the latter towards absorption. Experiments indicate that the micromachined V-bend fiber refractometer is most sensitive when the bend angle is centered around 140 degrees, at which angle the sensor may resolve changes in refractive index as small as 0.00015. Additionally, the V-bend sensor was found to be non-responsive toward sample absorption even in extremely absorbing solutions. The air-gap design absorption sensor, most commonly used for measurements in highly colored media, was found to be slightly sensitive towards refractive index. When the two sensors are used together, the response of the absorption sensor may be corrected for. This sensor combination is able to provide accurate measurements in situations where Beer's law is not obeyed. Results are presented that show that the sensor pair was successfully used to monitor wine sugar content (Brix), and color density and hue, parameters related to the age of the wine.