Abstract
Select search scope: search across all journals or within the current journal

The insertion of central venous catheters through the femoral veins is not uncommon and is potentially associated with the risk of immediate puncture-related complications and severe late complications as infection and thrombosis. As for other central venous access devices, the use of a standardized protocol of insertion and the correct application of evidence-based strategies are beneficial in reducing the risk of complications. We proposed a standardized protocol (S.I.F.: Safe Insertion of Femorally Inserted Central Catheters) consisting of seven strategies that should be part of vascular cannulation and should be adopted during the insertion of femoral venous catheters, aiming to minimize immediate, early and late insertion-related complications. These strategies include: preprocedural evaluation of the patient history and of the veins, appropriate aseptic technique, ultrasound guided puncture and cannulation of the vein, intra-procedural assessment of the tip position, adequate protection of the exit site, proper securement of the catheter, and appropriate coverage of the exit site.
One of the most challenging aspects of providing end-stage kidney disease care is to achieve adequate long-term access to the bloodstream to support hemodialysis (HD) therapy. Although upper extremity arteriovenous fistula remains the vascular access of choice for patients on HD, complications such as central venous stenosis, access thrombosis, or exhaustion of suitable access sites in the upper extremity, ultimately result in pursuing vascular access creation in the lower extremity. The current review focuses on the indications, contraindications, and clinically relevant practical procedural tips to successfully place a tunneled femoral dialysis catheter. The review highlights some of the prevailing misconceptions regarding femoral catheter placement practices.
Establishing a forearm arteriovenous fistula (AVF) offers preferred cannulation sites and preserves proximal access opportunities. When a radiocephalic AVF at the wrist is not feasible and the upper arm cephalic and median cubital veins are inadequate, an AV graft or more complex access procedure is often required. Creating a retrograde flow forearm AVF (RF-AVF) is a valuable alternative where the mid-forearm median antebrachial or cephalic vein is adequate, offering forearm cannulation zones with AVF outflow through deep and superficial collaterals. We report our technique and results.
We retrospectively reviewed our vascular access data base of consecutive patients during an 11-year study period where a RF-AVF established the only available cannulation target in the forearm. In addition to physical examination, all patients had ultrasound vessel mapping.
A forearm access was established with a RF-AVF as the only opportunity for cannulation in 48 patients. Ages were 14–86 years (median = 62 years). Forty-four percent female, 63% diabetic, 13% obese, and 29% had previous access operations. Inflow was proximal radial artery in 47 individuals and one proximal ulnar. Nine AVFs (19%) failed at 2–66 months (median 14 months). One RF-AVF was ligated due to arm edema. Follow-up was 2–111 months (median = 23.5 months). Primary and cumulative patency rates were 62% and 91% at 12 months, and 46% and 85% at 24 months. Five patients were lost to follow-up with functioning RF-AVFs (mean 41 months). Twenty-three patients (48%) died during F/U of causes unrelated to access procedures (mean 25 months).
Establishing a reverse flow forearm AVF offers a successful autogenous access option in the forearm for selected patients with an inadequate distal radial artery and/or cephalic vein at the wrist, avoiding more complex or staged procedures and preserving upper arm sites for future use. A proximal radial artery inflow procedure is recommended.
Due to the long waiting time for kidney transplantation, most End-Stage renal disease patients are commenced on either hemodialysis or peritoneal dialysis. Reusable fistulas have the lowest risk for death, cardiovascular events, and infections among all vascular accesses. This study aims to report the outcomes of the arteriovenous fistulas and PTFE grafts and the related predictive clinical and demographic variables.
This retrospective study reviewed the charts of all hemodialysis patients between January 2017 and January 2021 at the Dialysis Center of An-Najah National University Hospital, Nablus, Palestine. Our outcomes were a primary failure, primary and secondary patency, and the related factors. Survival analysis using the Kaplan-Meier method was conducted, and the log-rank test was used to compare patency rates. The Cox proportional hazards regression model tested factors relevant to primary and secondary patency rates in univariate and multivariate analyses.
A total of 312 procedures were performed during the study period. Primary failure was 7.1% for AVF, 13.9% for arterio-venous graft (AVG) procedures. Peripheral arterial disease and left-sided AVF were associated with more primary failure rates. AVF, primary patency rates at 1, 2, and 3 years were 82%, 69%, and 59%, respectively, while secondary patency rates at 1, 2, and 3 years were 85%, 72%, and 63%, respectively. Factors associated with increased AVF patency in a proportional hazard model were younger age and dual antiplatelet administration.
Our study adds further evidence that autogenous AVF has better results than prosthetic AVG in both primary and secondary patency rates as well as less primary failure rates. Therefore, we encourage further longitudinal studies that assess the benefits of using antiplatelet on AVF outcome versus risks of bleeding, especially with dual agents.
Peripheral venous access for extracorporeal photopheresis (ECP) may be difficult in graft versus host disease (GVHD) patients, because of previous intravenous therapies and multiple peripheral cannulations; in this population of patients, ultrasound guided midline catheters may be an alternative option to central venous access.
In this single-center, prospective preliminary study, we enrolled all consecutive patients with a diagnosis of GVHD and candidate to ECP, over a period of 10 months. We used inserted power injectable, non-valved, polyurethane, 20–25 cm single lumen midline catheters (MC).
Sixty-nine ECP procedures were carried out in six patients, using single-lumen MCs for outflow (5Fr in 74% and 4Fr in 26% of cases). For inflow, we used 5Fr or 4Fr MCs, or central venous access devices previously placed for other clinical reasons. There were no catheter-related complications during the entire period of ECP treatment. Mean outflow was significantly higher for 5Fr than for 4Fr MCs (35.8 ± 7.3 vs 29.2 ± 7.8 ml/min;
In GVHD patients, ECP can be performed efficiently and safely using single lumen polyurethane power injectable MCs. The best results are obtained with 5Fr rather than with 4Fr catheters. This strategy of venous access should be implemented in DIVA patients requiring ECP treatments, and probably also in other types of apheresis.
The extent of vascular/venous access device (VAD) research output from the Island of Ireland is unknown. The identification of the papers available is important to create a future research agenda.
The main objective of this study is to answer three questions: What is the number and descriptive quality of reported Vascular Access Device literature from the Island of Ireland? Is the reporting of Catheter Related Infection rates for cancer patients common in Irish Hospital Groups, National Cancer Reports and Publication Outputs? What are the implications for future research in this area?
We used a scoping review and searched selected databases, grey literature and hospital regulatory bodies websites following the Joanna Briggs Institute Guidelines 2017. A data charting form was developed based on a template from the Joanna Briggs Institute and this was used to extract data from the included reports.
A total of 660 reports were screened. Sixty-one full text articles were reviewed from which 20 reports were included for data extraction. Of the reports included the following designs were used: nine retrospective study designs, four guidelines, two prospective study designs, two literature reviews and one of the following; survey, case study and cross sectional analysis designs. We did not identify any randomised controlled trials, systematic reviews, meta-analysis, meta-synthesis and scoping reviews. Five studies included catheter related infection rates. Gaps in the research include the collection of data sets and the need to establish a VAD registry; develop core outcomes for VADs; assessment and evaluation of VAD care bundles among cancer patients; and, the inclusion of public and patient involvement in future VAD research.
The reporting of VAD outcomes in published literature regarding cancer patients receiving treatment in Ireland is inconsistent and varied with no interventional studies addressing vascular access complications in cancer care.
Aim of Arch V SUPERA-LUX was to evaluate the safety and efficacy of the combination therapy of SUPERA™ (
Investigator-initiated, single-center, single-arm prospective pilot study of 20 end-stage renal failure Asian patients with a dysfunctional brachiocephalic fistula. All had symptomatic recurrent CAS within 6 months of prior intervention. The lesion was pre-dilated with a standard high-pressure balloon (Biotronik Passeo-35 HP balloon). The DCB (Passeo-18 Lux™) is subsequently inflated and the SUPERA™ stent deployed to sit 2 mm distal to the cephalic arch and covering the CAS but within the DCB zone. All patients were prescribed dual antiplatelet therapy for 3 months and followed up with Duplex ultrasound at 6- and 12-months.
There were 9 (45%) males and mean age was 67 ± 11.0 years. Mean time from prior procedure was 113 ± 68 days and main indication for reintervention was high venous pressure (9/20, 45%). Technical success was 100% and there were no peri-procedural complications related to either stent or DCB deployment. Target lesion primary patency at 6- and 12-months was 10/18 (55%) and 5/16 (31%), respectively. Mean time to target lesion re-intervention was 170 ± 82 days. Circuit access patency was 8/18 (44%) and 2/16 (13%) at 6- and 12-months respectively and mortality was 3/20 (15%) attributed to the patients’ underlying co-morbidities.
Dual prong strategy of using SUPERA™ stenting and Passeo-18 Lux™ drug elution for recurrent CAS, although safe, was no more efficacious than conventional balloon angioplasty or stenting alone. Development of an intense inflammatory reaction within the stent led to reinterventions of a number of cases with suboptimal results.
Tunneled hemodialysis catheter-related bloodstream infection is a major cause of morbidity and mortality in end-stage renal disease patients. Side holes positioned near the tip of catheters have been linked to formation of thrombi, which, in turn, have been implicated in predisposition to infection. In addition, side holes allow spillage of catheter locking solution, including antibiotics, thereby minimizing the lock solution’s effect on the catheter tip. This study assessed the infection events that occurred in a series of hemodialysis patients using a non-side-hole catheter.
Over a period of 2 years, a novel symmetric-tip non-side-hole catheter was placed in 60 patients. Hemodialysis was performed thrice weekly. Prescribed dialyzer flows were 300–350 mL/min. Catheters were routinely locked with heparin 5000 units/mL between treatments. Patients were followed up for any catheter related complications, specifically infection events.
Seven events of catheter-related bloodstream infection occurred for a rate of 0.76 events per 1000 catheter-days, with the first event occurring 9 weeks after insertion. These events were treated by locking the affected catheter with 2 g of clindamycin in 2 mL of heparin 1000 units/mL and administration of intravenous antibiotics, in most cases, for 7–14 days. Two catheters were removed due to infection.
Catheter-related bloodstream infections with non-side-hole hemodialysis catheters do occur at a relatively low rate and in this initial preliminary study it seems that most of these infections can be successfully treated without removal of the affected catheters.
The age and number of comorbidities in the hemodialysis population has increased over time. This may influence the construction and survival of the arteriovenous fistula (AVF). The present study explored the incidence and survival of AVFs over a period of 39 years.
A retrospective cohort study was conducted based on Danish registries. Incident hemodialysis patients between 1977 and 2015 were included. The incidence of AVF and factors associated with the construction of an AVF were described. Risk factors for AVF survival and repair were explored by Kaplan Meier and Cox proportional hazard analysis.
The total number of arteriovenous accesses (AVF and arteriovenous grafts) were 10,187 and there were 4201 central venous catheters (CVC). No significant difference in the proportion of AVFs during the 39 years was seen. Age and renal diagnosis did not influence the proportion of AVFs. Patients with CVCs were found to have a significantly higher prevalence of comorbidities (
Despite an older dialysis population, the proportion and survival of the AVF in the Danish dialysis population has not changed, probably because of increased awareness of AVF as the first choice of vascular access and improved surveillance, surgery, and repair.
Ultrasound-guided peripheral intravenous catheter (USGPIV) insertion is an effective method to gain vascular access in patients with difficult intravenous access (DIVA). While USGPIV success rates are reported to be high, some studies have reported a concerning incidence of USGPIV premature failures.
The purpose of this study was to compare differences in USGPIV and landmark peripheral intravenous catheter (PIV) utilization and failure following a hospital-wide USGPIV training program for nurses.
The authors performed a retrospective, electronic medical record review of all USGPIVs and PIVs inserted at a tertiary, urban, academic medical center from September 1, 2018, through September 30, 2019. The primary outcome was differences between USGPIV and PIV time to failure.
A total of 43,470 short peripheral intravenous catheters (PIVCs) were inserted in 23,713 patients. Of these, 7972 (16.8%) were USGPIV. At 30 days of follow-up, for PIVCs with an indication for removal documented, USGPIVs had higher Kaplan–Meier survival probabilities than PIVs (
The use of simulation-based mastery associated with USGPIVs, demonstrated lower failure rates than standard PIVs after 2 days and USGPIVs exhibited improved survival rates in patients with DIVA. These findings suggest that rigorous simulation-based insertion training demonstrates improved USGPIV survival when compared to traditional PIVCs. SBML is an extremely useful tool to ensure appropriately trained clinicians acquire the necessary knowledge and skillset to improve USGPIV outcomes.
Quantitative physical examination (PE) indicators, including palpable pulsatility length and outflow scores, can be used to quantify stenosis severity at hemodialysis vascular access sites. It is known that the risk of high-shear-related thrombosis is increased when the minimal luminal diameter (MLD) of stenosis decreases. At present, MLD is measured using sonography or angiography. This study sought to determine the relationship between quantitative PE indicators and MLD and report their diagnostic performance in detecting patients with stenosis at a high risk of thrombosis.
We performed a retrospective case–control study using routinely collected data. We used the post-stenosis palpable pulsatility length (sPPL) and pulse-and-thrill based outflow score to assess the severity of AVF inflow and outflow stenosis, respectively. We recorded paired quantitative PE indicators and MLD before and after angioplasty in patients enrolled over a 4-month period.
A total of 249 paired PE indicators and MLD measurements were obtained from 163 patients. A receiver operating characteristic curve analysis showed that an MLD cutoff value of <1.55 mm and an MLD of <1.95 mm discriminated sPPL = 0 and PESOS (physical examination significant outflow stenosis)/1− of the outflow score, respectively, from all other measurements, with the area under the curve values of 0.8922 and 0.9618, respectively. With sPPL = 0 and PESOS/1− of the outflow score as diagnostic tools to detect inflow stenosis with an MLD of ⩽1.5 mm and outflow stenosis with an MLD of ⩽1.9 mm at vascular access sites, sensitivity = 86.00% and 88.46%; specificity = 97.67% and 92.11%; positive predictive values of 97.73% and 92.00% and negative predictive values of 85.71% and 88.61%, respectively, were observed.
Our preliminary results showed that physical examination can potentially be a diagnostic tool in detecting patients with stenosis who are at a high risk of thrombosis at hemodialysis vascular access sites with high diagnostic accuracy.
The application of peripheral intravenous catheter has been an effective guarantee for the success of pediatric therapy. We aimed to investigate the correlative factors that impacting the duration of pediatric peripheral intravenous catheter.
From January 2017 to October 2017, 370 cases of pediatric patients in the First Hospital of Hunan University of Chinese Medicine were collected as the research object. Based on the indwelling time, the collected cases were divided into two groups, namely long time group (>72 h) and short time group (<72 h). The general data and laboratory test results of two groups were collected, and the correlation factors of indwelling time were analyzed by single factor and Logistic multiple factors.
As the results revealed that compared with short time group, patients in long time group had statistically significant differences in puncture site, phlebitis, extravasation of blood vessels, hemoglobin, white blood cells, platelets, and 75% ethanol sterilization (
Analyze factors influencing indwelling time of pediatric peripheral intravenous catheter and enhance the management of relevant factors are of great significance to prolong the indwelling time, reduce the pain of pediatric patients, and facilitate the clinical medication.
Occupational exposure to cytotoxic drugs can lead to significant health problems. This study was designed to evaluate the risk of 5-fluorouracil (5-FU) contamination for nurses when disconnecting the infusion line of an elastomeric pump from a non-coring needle, by comparing three configurations: the first one using standard Male and Female Luer lock (Group 1), the second one using a needle-free connector (NFC) and a Male Luer lock (Group 2) and the third one using a closed-system transfer device (CSTD), Qimono® (Group 3).
In this in vitro study, 10 elastomeric pumps for each of the three groups were filled with 5-FU and a tissue mimicking the patient’s arm was placed below the connection between the infusion line and the tubing of non-coring needle. After 48 h of infusion, disconnection was performed by a nurse with a wipe soaked in a mix of chlorhexidine and isopropyl alcohol in order to mimic care practices. For each pump, the tissue, the pair of gloves and the wipes used during the disconnection were collected for analysis.
Median level of overall 5-FU contamination (gloves + wipes + tissues) in group 3 was significantly lower than in group 1 (
The use of Qimono® appears to significantly reduce 5-FU contamination when disconnecting infusion lines of an elastomeric pump unlike NFC and standard Luer lock.
Maintaining patent access is essential for haemodialysis dependent end stage renal failure patients. The COVID-19 pandemic has significantly affected surgical and interventional radiology services worldwide. We aimed to review the impact COVID-19 has caused to the management of acute dialysis access thrombosis.
We conducted a single centre retrospective review of outcomes of patients with arteriovenous fistula and arteriovenous graft thrombosis between March and May 2020, which coincided with the first peak of the COVID-19 pandemic in London, and a similar period in the previous year, March–May 2019. Outcomes in both cohorts of patients were compared, including attempts at salvage, salvage success, 1-month patency rates after salvage and subsequent surgery on the same access. We also analysed the use of tunnelled haemodialysis lines (THL), either due to failed salvage attempts or when salvage was not attempted.
There was a similar incidence of access thrombosis in both periods (26 cases in 2019, 38 in 2020). There were 601 patients dialysing via an arteriovenous fistula or graft in 2019, and 568 patients in 2020. Access salvage, when attempted, had similar success rates and 1-month patency (salvage success 74% vs 80%,
During the peak of the COVID-19 pandemic, there were fewer attempts at access salvage. This was a conscious decision due to increased pressure on the healthcare system, access to emergency interventional radiology or operative theatres and the perceived risk/benefit ratio of access salvage. The long-term effects of this change in practice remain unknown.
We sought to evaluate differences in primary anesthetic type used in arteriovenous access creation with the hypothesis that administration of regional anesthesia and monitored anesthesia care (MAC) with local anesthesia as the primary anesthetic has increased over time.
National Anesthesia Clinical Outcomes Registry data were retrospectively evaluated. Covariates were selected a priori within multivariate models to determine predictors of anesthetic type in adults who underwent elective arteriovenous access creation between 2010 and 2018.
A total of 144,392 patients met criteria; 90,741 (62.8%) received general anesthesia. The use of regional anesthesia and MAC decreased over time (8.0%–6.8%, 36.8%–27.8%, respectively; both
Use of regional anesthesia and MAC with local anesthesia for arteriovenous access creation has decreased over time with general anesthesia remaining the primary anesthetic type. Anesthetic choice, however, varies with patient characteristics and geography.
Although tunneled dialysis catheters (TDC) are far from ideal, they still represent the main form of vascular access for most patients beginning dialysis. Catheters are easy to place and allow patients instant access to dialysis, but regardless of these benefits, catheters are associated with a high incidence of significant complications like bloodstream infections, central venous stenosis, thrombosis, and dysfunction. In the present study, we aim to describe and characterize a swine model of catheter dysfunction and bloodstream infection, that recreates the clinical scenario, to help to serve as a platform to develop therapeutic innovations for this important clinical problem.
Six Yorkshire cross pigs were used in this study. Non-coated commercial catheters were implanted in the external jugular recreating the main features of common clinical practice. Catheters were aseptically accessed twice a week for a mock dialysis procedure (flushing in and out) to assess for and identify catheter dysfunction. Animals were monitored daily for infections; once detected, blood samples were collected for bacterial culture and antibiograms. Study animals were euthanized when nonresponsive to treatment. Tissue samples were collected in a standardized fashion for macroscopic inspection and histological analysis.
The data analysis revealed an early onset of infection with a median time to infection of 9 days, 40% of the isolates were polymicrobial, and the average time to euthanasia was 20.16 ± 7.3 days. Median time to catheter dysfunction onset was 6 days post-implantation. Postmortem dissection revealed external fibrin sheath and internal thrombosis as the main causes of catheter dysfunction. There was also evidence of central venous stenosis with positive cells for αSMA, CD68, Ki67, Smoothelin, and Vimentin within the venous neointima.
The described model represents a reliable and reproducible large animal model of catheter dysfunction and bloodstream infection, which recreates all the main complications of TDC’s and so could be used as a validated large animal model to develop new therapies for TDC related infection, thrombosis/dysfunction and central venous stenosis.
The objective of this study was to evaluate whether the choice of intravenous access (IVA) site affects aortic attenuation during thoracic computed tomographic angiography (T-CTA) and any associated risks with intravenous device placement.
All T-CTA exams performed between 1/1/2013 and 8/14/2015 were retrospectively reviewed to identify those performed with contrast media injection via alternative (i.e. non-antecubital) IVA (
Hand/wrist, arm, and central venous access device IVA were all equivalent to antecubital IVA in terms of attenuation (
Satisfactory aortic attenuation achieved with non-antecubital IVA is equivalent to attenuation achieved with antecubital IVA for T-CTA imaging. The risk of contrast media extravasation in peripheral IVA devices was relatively low, however, appropriate IVA site selection should be considered an important factor for successful administration of contrast media for future imaging studies. This prevents undue harm to patients through preventable device failures when using a peripheral IV device in areas of high flexion/range of movements undergoing pressure injection for contrast media.
Native autologous arteriovenous fistula (AVFn) is the preferred vascular access for hemodialysis due to its long term patency and low complication rate. A challenging limitation is the anatomical inability to perform AVFn and failure of maturation. Preoperative isometric exercise (PIE) can increase vascular calibers and improve the rate of distal AVF. However, it is unknown whether PIE might enhance the performance of AVFn in patients who are not initially candidates.
A retrospective observational study was conducted over a population of 45 patients evaluated in vascular access clinic, 23 were not initially candidates for radiocephalic (NRC-AVF) and 22 were not candidates for autologous fistula at all (NA-AVF). They were assigned to perform PIE with handgrip device and revaluated.
After 4–8 weeks of PIE, a AVFn was performed in 16 patients from NA-AVF group and a radiocephalic AVFn was performed in 21 patients from NRC-AVF group. Both groups experienced a significant and similar increase in venous caliber 0.91 ± 0.43 mm in NA-AVF versus 0.76 ± 0.47 mm in NRC-AVF (
PIE allowed the allocation of an AVFn in patients not initially candidates, but entailed a high rate of maturation failure. Patients not candidates to radiocephalic AVF benefited from PIE and preserved a long term usability of AVF for dialysis.
We investigated physical and chemical stability of daptomycin and vancomycin in heparin or sodium citrate lock solutions. The aim of this study was to find the optimal combination of antimicrobials and additives for lock solutions, which maximized patient safety.
Vancomycin and daptomycin were diluted with heparin or sodium citrate to achieve final concentrations of vancomycin-heparin 2.5 mg/mL–833.33 U/mL, vancomycin-citrate 2.5–33.3 mg/mL, daptomycin-heparin 5 mg/mL–800 U/mL, and daptomycin-citrate 5–32 mg/mL and they were stored at room temperature (+25°C), 4°C, −20°C, and 37°C. Physical and chemical stability were analyzed for each antibiotic-anticoagulant combination in all conditions immediately after preparation, at 24, 48, 72 h and at different time points until unstable concentrations were obtained. Daptomycin-sodium citrate microbiological activity was also studied by evaluating two Staphylococcus aureus cultures in a calcium enriched medium with a daptomycin E test, with and without sodium citrate.
After incubation at 37°C vancomycin and daptomycin combined with heparin retained at least 90% of the initial concentration over 48 h. Vancomycin-sodium citrate solution stored at 37°C reduced more than 10% of the initial concentration at 24 h. On the other hand, daptomycin-sodium citrate preparation was stable at 37°C for 72 h but the microbiological activity of daptomycin was lower in the presence of sodium citrate.
The purpose is to prepare vancomycin and daptomycin lock solutions combined with heparin. They should be changed at 48 h and its stability is over 3 days at 25°C and 7 days at 4°C, which allow Hospital Pharmacy Services to manage their stocks. Daptomycin-sodium citrate combination is more stable for extended periods but its bioactivity has not been demonstrated.
A self-administered 11 item vascular access specific quality of life measure (VASQoL) was previously derived from detailed qualitative interviews with adult patients with kidney failure who have experienced vascular access using the Capabilities Approach as a theoretical base. This study reports the psychometric validation of the VASQoL measure including its reliability, content validity and responsiveness to change.
Cognitive interviews were conducted with 23 adult patients with kidney failure after completion of the VASQoL measure. Focus group discussion with a vascular access professional multidisciplinary team was undertaken (
Transcript analysis of cognitive interviews after VASQoL completion indicated that the content was comprehensive and well understood by participants. Assessment of Internal reliability for the VASQoL measure was high (Cronbach’s alpha 0.858). Test-retest reliability of the overall VASQoL measure was high (intra class correlation coefficient 0.916). In those patients who experienced a vascular access event, significant differences were observed in paired analysis of the VASQoL physical domain questions and vascular access function domain questions and in the EQ-5D usual activities, pain and anxiety domains. In those with no vascular access event, variation was observed in longitudinal analysis in VASQoL questions relating to worry about VA function and capability domains, whilst no variation was observed in the EQ5D measure.
The VASQoL measure has good internal consistency, test-retest reliability, convergent validity and responsiveness to change for clinically relevant vascular access outcomes. This provides a validated, vascular access specific quality of life measure that can be used in future trials of vascular access, evaluation of new technologies and routine use as a patient reported outcome measure (PROM).
Endovascular therapy, such as percutaneous transluminal angioplasty (PTA), stenting, or embolization, is a well-established form of treatment to prolong the lifespan of arteriovenous access. These procedures, especially PTA, can be accompanied with severe pain. We reviewed and analyzed the efficacy, safety, and outcome of sedoanalgesia using intravenous midazolam and fentanyl, for pain relief during these procedures.
Two hundred and two consecutive patients with dysfunctional dialysis access that had undergone endovascular procedure in our institute between July and November 2017 were included in this study. The dialysis access profile, procedure complication, and 10-point Visual Analog Scale (VAS) were collected. One-year clinical follow-up record was also collected to evaluate arteriovenous access patency and long-term complications.
Among the 202 patients, the mean age was (mean ± SD) 67.0 ± 12.08 years. Dialysis access profile of these patients were 119 (58.9%) native arteriovenous fistula and 162 (74.2%) forearm access. The number of lesions treated were 1.63 ± 0.802.
Immediate complications included 11 (5.44%) nausea/vomiting, 24 (11.88%) desaturation (SpO2 < 90%, resolved after pillow removal or jaw trust), 16 (7.9%) hypotension (SBP < 90 mmHg, resolved without inotropic agents). There was a low average pain score (1.16 ± 1.594) during the procedure with 136 (67.3%) no pain (VAS 0–1) and 56 (27.7%) mild pain (VAS 2–4). Higher VAS score correlated with overweight patients, longer PTA time and pain after procedure. Six-month primary patency rate was 49.17% and primary assisted patency rate was 93.04%.
Sedoanalgesia with intravenous midazolam and fentanyl is an easy, safe, and effective method for surgeons.
The arteriovenous fistula (AVF) is the preferred vascular access for End Stage Renal Disease, having superior patency and lower infection risks than prosthetic graft and catheter access. When AVF dysfunction or delayed maturation does occur, the gold standard for diagnosis is the fistula angiogram (a.k.a. fistulogram). 3D ultrasound is available for obstetrical and other specialized uses, but it is cost prohibitive and has a field of view that is too small to cover the region of interest for the dialysis fistula application. We sought to develop a point of care 3D solution using freehand 2D ultrasound data acquisition.
We developed open-source software for 3D image reconstruction and projection of an angiogram-like image of the vascular access using a 2D freehand ultrasound scanner. We evaluated this software by comparing the ultrasound “sono-angiogram” images to fistulogram images in five subjects, using visual inspection and by applying the Percent of Exact Match (PEM) as a statistic test.
The sono-angiograms showed identifiable characteristics that matched the fistulogram results in all five subjects. The PEM ranged between 42.8% and 77.0%, with Doppler and grayscale ultrasound data, showing complementary advantages and disadvantages when used for sono-angiogram image construction. Motion from freehand ultrasound acquisition was a significant source of mismatch. 3D image generation is a potential advantage with ultrasound data.
While further work is needed to improve the accuracy with free hand scanning, fistulogram-like “sono-angiograms” can be generated using point of care 2D ultrasound. Methods such as these may be able to assist in point-of-care diagnosis in the future. The software is open-source, and importantly, the ultrasound data used are non-proprietary and available from any standard ultrasound machine. The simplicity and accessibility of this approach warrant further study.
In 2011, Dawson proposed the Zone Insertion MethodTM (ZIMTM) to identify the optimal peripherally inserted central catheters (PICCs) insertion site in the upper arm. However, data on the effectiveness and safety of the ZIMTM in guiding PICC placement in Chinese population is limited.
In this randomized controlled trial, 120 cancer patients were randomly assigned to the upper portion of the red zone (RZ), the green zone (GZ) and the lower portion of the yellow zone (YZ) groups (at a 1:1:1 ratio). The aim was to compare the degree of patient comfort and the incidence of major PICC complications among the three insertion zones based on the ZIMTM in a Chinese Cancer Center. (Clinical Trials. Gov number, ChiCTR1900024111)
A total of 118 catheters were inserted in 118 patients (2 patients were lost to follow-up). After the 1-month follow-up, patients randomly assigned to the YZ group had a higher degree of comfort with a lower score than those assigned to the other two zone groups: 30.21±3.16 in the YZ group versus 31.65±2.51 in the RZ group and 31.59±2.92 in the GZ group (
This study found that the lower portion of YZ seems to be another suitable PICC insertion site for a higher degree of comfort and a lower risk of occlusion and thrombosis, which broadens the choice of PICC insertion sites in the upper arm for clinical practice.
The arteriovenous fistula (AVF) is the preferred vascular access for hemodialysis (HD) treatment and preservation of a stable vascular access is crucial. Long term Far Infrared Radiation (FIR) has been found to increase access flow together with an enhanced maturation and patency of the AVF. The acute effects of FIR on access flow have been sparsely described and the results are contradictory, perhaps due to differences in measurement conditions and other factors of importance for access flow.
Twenty patients in HD with an AVF were included. Each patient was randomized to receive either FIR (FIR group) or no FIR (control group). The acute changes in access flow were investigated in both groups on the second dialysis day of the week and during the first 1.5 h of the dialysis session. Concomitant changes in hemodynamic parameters of importance for access flow were also explored.
There was no significant change in access flow in the FIR group compared with the control group (median (Interquartile Range)) (−10 (−413.8; 21.3) ml/min vs −17.5 (−83.8; 76.3) ml/min,
In this trial, with a highly standardized set-up, one session of FIR did not result in any acute changes in access flow. This was not due to differences in the hemodynamic parameters between the groups.
Arteriovenous grafts (AVG) for haemodialysis (HD) access are recommended as a second line modality due to higher morbidity and mortality rates than arteriovenous fistulae (AVF). Smoking is already established as a risk factor in lower extremity bypass graft failure used for peripheral vascular disease, but its effect on AVGs remains unclear. We aimed to investigate the relationship of smoking on AVG outcomes.
A 3 year (01/08/2015–01/08/2018) multi-centre retrospective study was carried out on patients receiving an AVG for HD. Data included patient demographics, medical history, operation, type of graft, postoperative course and primary and secondary patency rates. Statistical analyses performed were Kaplan-Meier curves and Cox’s proportional hazard regression.
Fifty-five AVGs were performed (1052 AVF performed) in this period. The most common complication was thrombosis (38.9%). Primary patency at 6, 12 and 24 months were 55%, 45% and 44% respectively. Secondary patency at 6, 12 and 24 months were 63%, 56% and 54% respectively. Smoking was found to be a poor prognostic factor for primary (HR 3.734 (1.818–7.668 95% CI)
Primary patency rates are lower than previous reports whilst secondary patency is equivalent. Smoking results in a greater risk of thrombosis and poorer primary and secondary patency. This is recognised in vascular surgical grafts, but has not been previously described in AVGs for HD access. Smoking is a modifiable risk factor and as AVGs are typically used for end-stage vascular access patients. Pre-operative strategies to promote smoking cessation, including patient education and prehabilitation should be employed to improve outcomes.
Despite its potential advantages, ultrasound-guided cannulation of the axillary vein in the infraclavicular area is still rarely used as an alternative to other techniques. There are few large series demonstrating the safety and feasibility of this approach.
Retrospective analysis of data on patients undergoing ultrasound-guided, long-axis, in-plane infraclavicular axillary vein cannulation for the incidence of complications and the failure rate from two secondary-care hospitals.
The analysis included 710 successful attempts of axillary vein long-axis, in-plane, US-guided cannulation, and 24 (3.3%) failed attempts. We recorded a 96.7% success rate with an overall incidence of complications of 13%, mainly malposition (8.1%). There was one case of pneumothorax (0.14%), five cases of arterial puncture (0.7%), and two cases of brachial plexus injury.
The US-guided axillary central venous cannulation (CVC) access technique can be undertaken successfully in patients, even in challenging circumstances. Taken together with existing work on the utility and safety of this technique, we suggest that it should be adopted more widely in clinical practice.
The present study aimed to determine the pain experienced by children during intravenous bolus treatment and to identify what causes it.
In the first stage of the study, the first 40 observations were performed by two researchers. The study was continued by a single observer after the Kappa test was performed. In this study, 101 drug treatments were administered by intravenous bolus in patients aged between 1 month and 6 years. The pain experienced during treatment was assessed using pain scales according to the age group the patient was in.
Pain was observed in 63.4% (
Intravenous drug therapy may cause pain in children. To minimize such pain, it is recommended to determine the drugs that cause pain during intravenous treatment and to develop application protocols to minimize pain caused by these drugs.
Along with the challenges to strengthen patient safety in the use of short peripheral catheters (SPCs), various studies have been conducted in the past to explore differences between two main types of SPCs—integrated SPC (ISPC) and simple SPC (SSPC) in terms of clinical performance. The accumulated evidence from the literature lean toward the benefits of ISPC use in preventing complications leading to longer dwell time and more economical savings than SSPC use. The study aimed to compare ISPC and SSPC in terms of first-attempt successful insertions, number of attempts before successful insertion, perceived ease of insertion, dwell time, reinsertion rate, reasons for removal, and costs of supplies used for the insertions. Furthermore, it aimed to verify whether the previous results of referenced work in the use of ISPC were similar, and its use provided more foreseeable benefit for patient safety and cost-efficiency.
This quasi-experimental study was conducted in a 650-bed tertiary academic medical center in the Philippines. Eligible participants were adult patients who were required SPC for at least 72 h by the physician. Using inferential statistics, comparisons were done among adult patients with integrated (
The successful first-attempt insertions did not vary significantly at around 80% in both groups (
ISPCs can yield the same results with that of SSPCs while being easier to use and less costly.
Epicutaneo-Caval Catheters (ECCs) are critical for good neonatal care. No previous studies have evaluated which insertion method provides the highest likelihood of success.
This study aimed to compare the success rates and cost of modified Seldinger technique (MST) and split needle technique (SNT). MST was introduced to St Michael’s Neonatal Unit, SNT was already in use. Routinely documented data on ECC insertion was retrospectively collected from the clinical notes. Practitioners were able to use their preferred insertion method. A sub-group analysis of success rates in patients born at ⩾35-weeks GA was performed.
There was a significantly higher first pass (53% vs 26%;
In this uncontrolled retrospective study, there was a higher chance of successful ECC insertion with MST, with a reduced number of venipunctures and similar costs per successful ECC. Further work in randomised studies is needed to verify this finding and should focus on other clinical outcomes, including rates in central line associated blood stream infections.
Hemodialysis forms the most common replacement therapy for majority of Indians suffering from chronic kidney disease (CKD). Multiple access failure and central vein stenosis has become commonplace in Indian dialysis access patients and there is a burgeoning need for more advanced hemodialysis (HD) access options. Upper thigh arterio-venous grafts (AVG) are seldom inserted due to fear of infection and limb ischemia.
This is a single institutional, retrospective, descriptive case study of consecutive patients who underwent upper thigh prosthetic AVG over a period of 7 years. All these patients had exhausted options of upper limb access and or had central vein stenosis. AVG from the proximal superficial femoral artery (SFA) to the proximal great saphenous vein (GSV) in a loop configuration using polytetrafluoroethylene (PTFE) was carried out in the upper thigh.
A total of 24 patients had undergone upper thigh loop AVG. Their age varied from 24 to 77 years. The median follow-up period was 3 years. Five of these grafts developed infection (21%) which led to primary failure. A primary patency of 71% (17/24 patients) was achieved at 1 year. Thrombosis developed at a mean of 16.7 months after the primary procedure. Adjunctive procedures such as thrombectomy, segmental replacement of graft, patch angioplasty, balloon angioplasty, and stenting were required in 75% of patients to achieve a secondary patency of 86% at 1 year. Three grafts were explanted without limb loss.
Upper thigh loop AVG forms a reliable alternate dialysis access option for patients with failed upper limb access sites or central vein occlusion. Adjunctive procedures are key to maintaining patency in these grafts. Good secondary patency is achievable, and the infection rates are similar to arm AVG. Close follow-up and timely intervention are key to long term dialysis through these grafts.
VAVASC study (Validation of Arterio Venous Access Stage Classification) is a multicentre, international, prospective study. The study aims to validate the AVAS classification, which is a classification system describing vascular status of patients indicated for creation of arteriovenous access on the upper limb.
Observational, prospective, multicentre, international study starting in March 2021. Participant recruitment has commenced. Basic demographic data, risk factors and vascular mapping parameters are collected via an online platform. The outcome measures are class of AVAS, predicted arteriovenous access, final arteriovenous access that has been created and a functionality of the arteriovenous access. Predictive models will be used for statistical analysis.
A total of 140 patients from 4 centres in Great Britain, Czech Republic, Brazil and Slovakia are already included and undergoing evaluation.
The study is registered in the Clinical trials registry (NCT04796558), https://register.clinicaltrials.gov/. Study is still open for collaboration with other centres that can register via www.vavasc.com.
We present the case of a patient with a brachio-basilic graft forearm loop with intractable edema and thrombosed central veins. She showed up with an important edema after some effort and a previously thrombosed pseudoaneurysm with significant growth. She refused angioplasty treatment for central veins, the graft had not been used for dialysis during the last year, so that arteriovenous graft (AVG) ligation was considered. Due to local conditions thrombin percutaneous embolization was performed to avoid possible complications of a conventional surgery approach. AVG occlusion was done in 10 min by fluoroscopy and ultrasound guidance. In 24 h the patient was significantly better and after 1 week she had no edema at all. There were no complications and no recanalization was observed after 3 months. Percutaneous thrombin embolization is a safe and effective technique for AVG occlusion in case of intractable arm edema with central vein thrombosis, and most likely to be considered in other situations where arteriovenous graft or fistula ligature is needed.
Persistent left superior vena cava (PLSVC) is a rare congenital anomaly. PLSVC can be associated with clinically significant atrial septal defect (ASD) or ventricular septal defect (VSD). It is usually asymptomatic and accidentally detected during invasive procedures or imaging examinations. However, whether central venous access device (CVAD) can be placed and used in patients with PLSVC is controversial. A total of six patients were diagnosed with PLSVC and confirmed by chest CT among 3391 cancer patients who underwent CVAD placement via intracavitary electrocardiogram (IC-EKG) at the Venous Access Center (VAC) from May 2019 to December 2020. The CVADs (peripherally inserted central catheter in four patients and Ports in two patients) of these six patients were left in PLSVC. We analyzed changes in the P-wave in the IC-EKG during CVAD placement and the characteristics of the body surface electrocardiogram in these patients and discussed the catheter tip position in PLSVC. All six patients showed negative P-waves in lead II via IC-EKG from the beginning of catheterization: four patients showed negative P-waves and two showed biphasic P-waves in the body surface electrocardiogram (lead III) before catheterization. CVAD function was normal and no obvious complications were observed during the treatment of these patients. The total retention time of CVADs was 1537 days. For patients with a negative P-wave in lead II via IC-EKG during catheterization, especially in those with a negative or biphasic P-wave in lead III of the body surface electrocardiogram, PLSVC should be considered. CVAD insertion in patients with type I PLSVC is safe under certain conditions, with the proper tip position in the middle to lower part of PLSVC.
Maintaining peripheral vascular access represents a major challenge for medical providers and patients leading to the emergence of ultrasound guided vascular access teams. Upper extremity peripheral vascular access options are often limited in the chronically ill patient population with end stage cancer, patients with severe contractures, tracheostomies, and feeding tubes and patients referred for palliative care are just some examples of patients who live with difficult access. The following is a case description of a mid-thigh superficial femoral vein midline catheter for comfort care medications in a patient with exhausted peripheral vasculature on hospice.
The Surfacer Inside-Out Access Catheter System (Surfacer) is a novel approach to restore access in total central vein occlusion (TCVO). We report a series of three cases, with mean 18-months follow up, in our institution where this technique was safely and effectively used in tandem with Hemodialysis Reliable Outflow (HeRO) graft for creation of upper limb vascular access in patients with TCVO. Although there have been reports describing the simultaneous combination of Surfacer and HeRO graft, to our knowledge, this is the first time where the outcomes with 18-months mean follow-up are reported. All three patients had failed prior conventional attempts at TCVO crossing and had exhausted most conventional upper limb vascular access methods. The above technique yielded a 100% technical success rate with mean operative time of 140 min. Cannulation rate was 100% with all undergoing successful early cannulation by post-operative day 3. Mean primary patency of 199 days was achieved. Average intervention rate of 1.2 a year was required to maintain patency. The Surfacer device used together with HeRO graft is a feasible technique to avoid femoral catheter in patients where conventional attempts to cross the TCVO have failed.
Successful hemodialysis treatment need a well functioning vascular access (VA) allowing two cannulation sites with enough blood flow have minimum adverse events. The expectations, age of the HD population are rising as well as the lack of conventional methods due to central venous exhaustion, we have to choose some complex access, including complex or tertiary vascular access mentioned in 2018 Clinical Practice Guidelines of the European Society for Vascular Surgery (ESVS) and the option to abandon the venous circuit in instead of arterial system, including arterial-arterial graft and arterial superficialization. This article report a complicated case of AVF dysfunction, central venous stenosis due to central venous catheter and aortic dissection stent as well as lower extremity arteriosclerosis occlusion, using the simple method of superficialization of enlarged radial artery to maintain hemodialysis.
Implanted ports have provided clinicians with long term venous accessibility, while maintaining comfort and convenience for their patients. One of the most commonly used implanted ports for oncological access is a Mediport (Norfork Medical, Skokie, IL). Guidelines (INS2021) strongly recommend placing central catheter tips at the cavo-atrial junction. In fact, too deep atrium position may be associated with micro-traumatism, possibly leading to a catheter associated right atrial thrombosis (CRAT). No significant literature discusses the possibility of such port masses being seeded by a bacteria, as in the case for endocarditis, which was seen in our patient. In the following case report, we will explore the case of a 41-year-old female with metastatic urothelial carcinoma who developed multiple right atrial masses possibly associated with a deeply seated totally implanted vascular access device (TIVAD) tip within the right atrial wall. These right atrial masses were of unknown origin, and in the setting of MRSA bacteremia, multiple possible etiologies would be discussed. We will also explore ways in which similar complications can be easily prevented in the future.
A 70-year-old man was admitted to the emergency department with recent spontaneous externalization of a metallic device from his right inner thigh. He had been experiencing mild local pain for 2 weeks and had a recent hospitalization due to cardiogenic hemodynamic instability, requiring a central venous catheter placement in his right internal jugular vein 3 months earlier. Doppler ultrasound confirmed the intravascular foreign body hypothesis as a guidewire was identified inside the right femoral vein, associated with femoropopliteal venous thrombosis. The guidewire was successfully removed percutaneously through simple manual traction guided by radioscopy. The patient was discharged the following day on oral anticoagulation with rivaroxaban. On outpatient follow-up 4 weeks post discharge, he had no complaints in the right lower limb except for slight swelling. Central venous catheterization is a common invasive procedure that, although unquestionably safe and well stablished in medical practice, can lead to serious complications when performed without proper technique.
The placement of large bore double-lumen catheters for hemodialysis (HD) is one of the most frequent procedures performed in HD patients. However, these procedures are associated with complications, the most common being catheter malposition. In this context, catheter deviation to the left superior intercostal vein (LISV) is a very uncommon malposition, which must be differentiated from intrathoracic extravascular catheter lodgment. We report a case of an adult male patient on hemodialysis who presented with a thrombosed arteriovenous fistula and requiring urgent HD. His past medical history included hemophilia, allergy to contrast media, and multiple previous central vein catheterizations. A non-tunneled HD catheter was placed without any difficulty in the left internal jugular vein. However, the arterial lumen failed to pull any blood with free flow in the venous lumen. A chest X-ray revealed a surprising finding. The malpositioned catheter was removed successfully without any complications.
We present the case of a 21-year-old male with significant lengthening and aneurysmal degeneration of his brachiocephalic arteriovenous fistula resulting in a megafistula and high-output cardiac failure. A computed tomography angiogram showed narrowing at the cephalic arch. Further evaluation during the operation revealed kinking and elongation of the fistula in addition to compression of the cephalic arch in the deltopectoral groove leading to outflow obstruction. The aneurysmal fistula was treated successfully with aneurysmorrhaphy of the remaining conduit and banding of the inflow. This case demonstrates a unique etiology of venous outflow obstruction for a fistula and describes the surgical approach to its treatment in a young patient suffering from cardiac failure.
The goal of the 2015 Michigan Appropriateness Guide for Intravenous Catheters (MAGIC) was to define indications and appropriate practices for peripherally inserted central catheters (PICC) use; however, MAGIC recommendations virtually reduced the use of PICC in hospital settings, including critical care. The aim of this review is to present an assessment of the MAGIC guidelines, considering contemporary evidence to date. The validity of the MAGIC recommendations and their applicability to current practice are called into question given important concerns with the methodology for their development (e.g. high volume of clinical scenarios for evaluation) and the supporting evidence used. There is a considerable amount of contemporary evidence not considered in MAGIC that reports on evolving practices, techniques, and technologies targeted to reduce complications associated with central venous access devices (CVADs). Recent evidence dictates that CVADs are necessary in the intensive care unit (ICU), and that PICCs are a safe, reliable, and appropriate type of central lines, which cannot be replaced in several ICU situations. In light of evolving evidence and practice, as well as the methodological concerns identified, the MAGIC guidelines should be revisited. It is also recommended to create a clinical assessment tool that identifies potential uses of specific CVADs, based on patient needs. The choice of the CVAD should be based on unique clinical considerations and current scientific evidence, not on fears informed by antiquated data.
The majority of hospitalized patients receive a Peripheral Venous Catheter (PVC) in the course of their treatment. Extravasation injury is a serious complication of intravenous treatment.
This cross-sectional survey designed study aims to investigate nurses’ knowledge and experience related to short peripheral venous catheter extravasation.
The study sample included 145 nurses working in a university hospital in the west of Turkey. A questionnaire developed in accordance with the literature was used for data collection. The data were assessed by frequency and proportions.
Of the nurses included in this study, 26.2% reported they had experienced extravasation injury in a patient; 74.5% said they had received no instruction in the management of extravasation during their in-service training program; and 85.5% stated they did not keep a record of extravasation. 89.7% of the nurses reported infused medications as a cause of extravasation, and 81.4% reported catheter sites as a cause. Among the medications reported by the nurses as causing extravasation: 89.7% reported contrast agents; 84.8% TPN solutions; 71.0% cytotoxic agents; and 65.1% mannitol. The symptoms of extravasation reported by nurses included: swelling (97.9%), redness (97.2%), pain (92.4%), rise in temperature (65.5%), and ulceration (60.0%). In responding to the occurrence of extravasation, interventions reported by the nurses included: stopping the flow of fluid (98.6%), elevation (89.7%), cold application (76.6%), and aspiration of drug (40.7%).
Based on these results, it is recommended that guidelines are developed for the management of extravasation, that periodic in-service training programs are provided and that observational studies are carried out into the administration of vesicant drugs.
The aims of our systematic review were to quantify the expected rate of procedural success, early and late complications during CIED implantation using US-guided puncture of the axillary vein and to perform a meta-analysis of those studies that compared the US technique (intervention) versus conventional techniques (control) in terms of complication rates. MEDLINE, ISI Web of Science, and EMBASE were searched for eligible studies. Pooled Odds Ratio (OR) and Pooled Mean Difference (PMD) for each predictor were calculated. The quality of evidence (QOE) was evaluated according to the GRADE guidelines. Thirteen studies were included a total of 2073 patients. The overall success of US-guided venipuncture for CIED implantation was 96.8%. As regards early complications, pneumothorax occurred in 0.19%, arterial puncture in 0.63%, and severe hematoma/bleeding requiring intervention in 1.1%. No cases of hemothorax, brachial plexus, or phrenic nerve injury were reported. As regards late complications, the incidence of pocket infection, venous thromboembolism, and leads dislodgement was respectively 0.4%, 0.8%, and 1.2%. In the meta-analysis (five studies), the intervention group (US-guided venipuncture) had a trend versus a lower likelihood of having a pneumothorax (0.19% vs 0.75%,