One of the major causes of aseptic loosening in an uncemented implant is the lack of any attachment between the implant and the bone. The implant’s stability depends on a combination of primary stability (mechanical stability) and secondary stability (biological stability). The primary stability may affect the implant–bone interface condition and thus influence the load transfer and mechanical stimuli for bone remodelling in the resurfaced femur. This paper reports the results of a study into the affect of primary stability on load transfer and bone adaptation for an uncemented resurfaced femur. Three-dimensional finite element models were used to simulate the intact and resurfaced femurs and the bone remodelling. As a first step towards assessing the immediate post-operative condition, a debonded interfacial contact condition with varying levels of the friction coefficient (0.4, 0.5, and 0.6) was simulated at the implant–bone interface. Then, using a threshold value of micromotion of 50 µm, the implant–bone interfacial condition was varied along the implant–bone boundary to mechanically represent non-osseointegrated or osseointegrated regions of the interface. The considered applied loading conditions included normal walking and stair climbing. Resurfacing leads to strain shielding in the femoral head (20–75 per cent strain reductions). In immediate post-operative conditions, there was no occurrence of elevated strains in the cancellous bone around the proximal femoral neck–component junction resulting in a lower risk of neck fracture. Predominantly, the micromotions were observed to remain below 50 µm at the implant–bone interface, which represents 97–99 per cent of the interfacial surface area. The predicted micromotions at the implant–bone interface strongly suggest the likelihood of bone ingrowth onto the coated surface of the implant, thereby enhancing implant fixation. For the osseointegrated implant–bone interface, the effect of strain shielding was observed in a considerably greater bone volume in the femoral head as compared to the initial debonded interfacial condition. A 50–80 per cent periprosthetic bone density reduction was predicted as compared to the value of the intact femur, indicating bone resorption within the superior resurfaced head. Although primary fixation of the resurfacing component may be achieved, the presence of high strain shielding and peri-prosthetic bone resorption are a major concern.
Bone void fillers that can enhance biological function to augment skeletal repair have significant therapeutic potential in bone replacement surgery. This work focuses on the development of a unique microporous (0.5–10 µm) marine-derived calcium phosphate bioceramic granule. It was prepared from
Homogenized elastic properties are often assumed for macro-finite element (FE) models used in orthopaedic biomechanics. The accuracy of material property assignments may have a strong effect on the ability of these models to make accurate predictions. For cortical bone, most macro-scale FE models assume isotropic elastic material behaviour and do not include variation of material properties due to bone micro-architecture. The first aim of the present study was to evaluate the variation of apparent-level (homogenized) orthotropic elastic constants of cortical bone with age and indices of bone micro-architecture. Considerable age-dependent differences in porosity were noted across the cortical thickness in previous research. The second aim of the study was to quantify the resulting differences in elastic constants between the periosteum and endosteum. Specimens were taken from the anterior femoral midshaft of 27 female donors (age 53.4 ± 23.6 years) and micro-FE (µFE) analysis was used to derive orthotropic elastic constants. The variation of orthotropic elastic constants (Young’s moduli, shear moduli, and Poisson’s ratios) with various cortical bone micro-architectural indices was investigated. The ratio of canal volume to tissue volume, Ca.V/TV, analogous to porosity, was found to be the strongest predictor (
Three models of different stent designs implanted in a cerebral aneurysm, originating from the Virtual Intracranial Stenting Challenge’07, are meshed and the flow characteristics simulated using commercial computational fluid dynamics (CFD) software in order to investigate the effects of non-Newtonian viscosity and pulsatile flow. Conventional mass inflow and wall shear stress (WSS) output are used as a means of comparing the CFD simulations. In addition, a WSS distribution is presented, which clearly discriminates in favour of the stent design identified by other groups. It is concluded that non-Newtonian and pulsatile effects are important to include in order to avoid underestimating WSS, to understand dynamic flow effects, and to discriminate more effectively between stent designs.
A small-scale biomechanical disc culture system was designed to stimulate intervertebral disc (IVD) ‘motion segment’ in culture environment with load-controlled compression and combined load (compression + shear). After 7 days of diurnal mechanical loading, cell viability of discs stimulated with static compression load (0.25 MPa) and static combined load (compression (0.25 MPa) + shear (1.5 N)) were similar (> 90 per cent) to unloaded controls. Mechanically stimulated discs showed decrease in static/dynamic moduli, early stress relaxation, and loss of disc height after 7 days of diurnal loading. Histological data of discs indicated load-induced transformations that were not apparent in controls. The feasibility of studying the mechanobiology of intact IVD as a motion segment was demonstrated. Media conditioning (improve tissue stability in long-term culture) and application of biochemical gene expression assays (differential tissue response to types of mechanical stimulation) are proposed as future improvements. The study suggests that the limitations in studying mechanobiology of IVD pathology
Previous research has demonstrated that the number of degrees of freedom (DOF) modelled at a given joint affects the antagonistic muscle activity predicted by inverse dynamics optimization techniques. This higher level of muscle activity in turn results in greater joint contact forces. For instance, modelling the knee as a 3 DOF joint has been shown to result in higher hip and knee joint forces commensurate with a higher level of muscular activity than when the knee is modelled with 1 DOF. In this study, a previously described musculoskeletal model of the lower limb was used to evaluate the sensitivity of the knee and hip joint contact forces to the DOF at the knee during vertical jumping in both a 1 and a 3 DOF knee model. The 3 DOF knee was found to predict higher tibiofemoral and hip joint contact forces and lower patellofemoral joint contact forces. The magnitude of the difference in hip contact force was at least as significant as that found in previous research exploring the effect of subject-specific hip geometry on hip contact force. This study therefore demonstrates a key sensitivity of knee and hip joint contact force calculations to the DOF at the knee. Finally, it is argued that the results of this study highlight an important physiological question with practical implications for the loading of the structures of the knee; that is, the relative interaction of muscular, ligamentous, and articular structures in creating moment equilibrium at the knee.