Spectroscopists' Calendar is a regular feature in
Calendar
Spectroscopists' Calendar
Abstract
Select search scope: search across all journals or within the current journal
Spectroscopists' Calendar is a regular feature in
WHAT'S NEW is provided as a service for our readers. It contains the latest news on the products, catalogs, tips, and supplies that manufacturers elect to highlight. Publication in WHAT'S NEW does not imply recommendation or endorsement by the Society for Applied Spectroscopy or the column editor. Contributions to WHAT'S NEW should be sent to
Applied Spectroscopy News is a monthly feature in the journal. It includes information from the Society for Applied Spectroscopy, news from other societies and institutions, announcements of meetings, schools, or other activities, and reports of symposia from recent conferences. If you have news items, a meeting announcement, or a report from a symposium that would be of interest to readers of
The science of surface plasmon polaritons, known as “plasmonics,” is reviewed from the viewpoint of applied spectroscopy. In this discussion, noble metals are regarded as reservoirs of photons exhibiting the functions of photon confinement and field enhancement at metallic nanostructures. The functions of surface plasmons are described in detail with an historical overview, and the applications of plasmonics to a variety of industry and sciences are shown. The slow light effect of surface plasmons is also discussed for nanoimaging capability of the near-field optical microscopy and tip-enhanced Raman microscopy. The future issues of plasmonics are also shown, including metamaterials and the extension to the ultraviolet and terahertz regions.
This is an unusual paper in that it does not address a particular research topic or present a novel experimental method or a new theoretical result. This paper addresses our basic understanding of the nature of the evanescent wave, the wave that is the basis of the entire field of Attenuated Total Reflection (ATR) spectroscopy. I recently had the opportunity to reexamine the foundations of ATR spectroscopy and was surprised to have had to change my own mental picture of the evanescent wave that I have built over the last 25 years. Over the years I have had numerous discussions with a large number of workers in the field as well as with my former mentor, and one of the originators and the principal developer of ATR spectroscopy, the late N.J. Harrick. Everything brought up in all these discussions was perfectly consistent with my old mental picture of the evanescent wave. Thus, I believe that the picture of the evanescent wave that I had is virtually universally held by workers in the field. This paper describes the new picture of the evanescent wave that emerged from said reexamination process.
The surface-enhanced coherent anti-Stokes Raman scattering (SECARS) from a self-assembled monolayer (SAM) of benzenethiol on a silver-coated surface-enhanced Raman scattering (SERS) substrate has been measured for the 1574 cm−1 SERS mode. A value of 9.6 ± 1.7 × 10−14 W was determined for the resonant component of the SECARS signal using 17.8 mW of 784.9 nm pump laser power and 7.1 mW of 895.5 nm Stokes laser power; the pump and Stokes lasers were polarized parallel to each other but perpendicular to the grooves of the diffraction grating in the spectrometer. The measured value of resonant component of the SECARS signal is in agreement with the calculated value of 9.3 × 10−14 W using the measured value of 8.7 ± 0.5 cm−1 for the SERS linewidth Γ (full width at half-maximum) and the value of 5.7 ± 1.4 × 10−7 for the product of the Raman cross section σSERS and the surface concentration
We report a time-correlated Raman spectroscopy technique based on a silicon photomultiplier (SiPM) and a time-correlated single photon counting (TCSPC) technique to exploit the natural temporal separation between Raman and fluorescence phenomena to alleviate the high fluorescence background with conventional Raman detection. The TCSPC technique employed can greatly reduce the effect of high dark count rate (DCR) and crosstalk of SiPM that seriously hinder its application in low light level detection. The operating principle and performance of the 400 ps time resolution system are discussed along with the improvement of the peak-to-background ratio (PBR) for bulk trinitrotoluene (TNT) Raman spectrum relative to a commercial Raman spectrometer with charge coupled device (CCD). The fluorescence lifetime for solid TNT and Surface Enhanced Raman Scattering (SERS) spectrum for 10−6 mol/L trace TNT have also been obtained by this system, showing excellent versatility and convenience in spectroscopy measurement.
Variable-temperature Fourier transform infrared spectroscopy (FT-IR) and Raman spectroscopic mapping measurements were applied to study the phase separation of a poly(3-hydroxybutyrate) (PHB)–poly(l-lactic acid) (PLA) (50:50 wt.%) polymer-blend film as a function of temperature between 25 and 175 °C. Because of the better band separation compared with the fundamental absorptions, the first overtones of the
Raman spectral data collected with high-resolution laboratory spectrometers are processed into a format suitable for importing as a user library on a 1064 nm DeltaNu first generation, field-deployable spectrometer prototype. The two laboratory systems used are a 1064 nm Bruker Fourier transform (FT)-Raman spectrometer and a 785 nm Kaiser dispersive spectrometer. The steps taken to adapt for device-dependent spectral resolution, wavenumber shifts between instruments, and relative intensity response are described. Effects due to the differing excitation laser wavelengths were found to be minimal, indicating—at least for the near-infrared (NIR)—that data can be ported between different systems, so long as certain measures are taken with regard to the reference and field spectra.
Maintaining appropriate temperatures and relative humidity is considered essential to extending the useful life of parchment artifacts. Although the relationship between environmental factors and changes to the physical state of artifacts is reasonably understood, an improved understanding of the relationship between the molecular conformation and changes to the macroscopic condition of parchment is needed to optimize environmental conditions. Using Attenuated Total Reflectance Fourier Transform Infrared Spectroscopy (ATR FT-IR) analysis, the conformation of the molecular structure in selected parchment samples with specific macroscopic conditions, typically discoloration and planar deformations (e.g., cockling and tearing), have been made. The results of this investigation showed that the Fourier transform infrared signal differs for parchment samples exhibiting different macroscopic conditions. In areas exhibiting planar deformation, a change in the Fourier Transform Infrared signal was observed that indicates unfolding of the molecular conformation. In comparison, the discolored samples showed a change in molecular conformation that indicates a chemical change within the collagen molecular structure. This paper discusses the possible causal associations and implications of these findings for the conservation and preservation of parchment artifacts.
Transient water absorption by cellulosic samples manufactured under varying pressure was monitored by near-infrared spectroscopy to explore the absorption behavior affected by the pressure. A substantial level of variation of the spectral features was induced by the water absorption and changes in the pressure. The detail of the spectral changes was analyzed with a multiple-perturbation, two-dimensional (2D) correlation method to determine the underlying mechanism. The 2D correlation spectra indicated that the compression of the cellulose increased the packing density of the samples, preventing the penetration of water. In addition, the compression substantially disintegrated its crystalline structure and eventually resulted in the development of inter- and intrachain hydrogen-bonded structures arising from an interaction between the water and cellulose. Consequently, the cellulose samples essentially underwent an evolutionary change in the polymer structure as well as in the packing density during the compression. This structural change, in turn, led to the seemingly complicated absorption trends, depending on the pressure.
We used near infrared spectroscopy to obtain concentration dependent glucose absorption spectra in aqueous solutions in the near-infrared range (3800–7500 cm−1). Here we introduce a new method to obtain reliable glucose absorption bands from aqueous glucose solutions without measuring the water displacement coefficients of glucose separately. Additionally, we were able to extract the water displacement coefficients of glucose, and this may offer a new general method using spectroscopy techniques applicable to other water-soluble materials. We also observed red shifts in the absorption bands of water in the hydration shell around solute molecules, which comes from the contribution of the interacting water molecules around the glucose molecules in solutions. The intensity of the red shift gets larger as the concentration increases, which indicates that as the concentration increases more water molecules are involved in the interaction. However, the red shift in frequency does not seem to depend significantly on the concentration. We also performed the same measurements and analysis with sucrose instead of glucose as solute and compared.
A standoff detection system was assembled by coupling a reflecting telescope to a Fourier transform infrared spectrometer equipped with a cryo-cooled mercury cadmium telluride detector and used for detection of solid-phase samples deposited on substrates. Samples of highly energetic materials were deposited on aluminum substrates and detected at several collector-target distances by performing passive-mode, remote, infrared detection measurements on the heated analytes. Aluminum plates were used as support material, and 2,4,6-Trinitrotoluene (TNT) was used as the target. For standoff detection experiments, the samples were placed at different distances (4 to 55 m). Several target surface temperatures were investigated. Partial least squares regression analysis was applied to the analysis of the intensities of the spectra obtained. Overall, standoff detection in passive mode was useful for quantifying TNT deposited on the aluminum plates with high confidence up to target–collector distances of 55 m.
We present a method for monitoring subtle (sub-wavenumber) dynamics within time-varying spectra. Peak fitting is performed for large numbers of spectra in a series, allowing for monitoring time evolutions of peak positions with high precision and confidence. Sub-wavenumber peak shifts due to physical or chemical changes in the sample can be monitored and their temporal evolution characterized. In surface-enhanced Raman scattering experiments, we were able to distinguish between slow photo-damage and fast conformational change dynamics. Fluctuations in peak positions of Raman spectra recorded from a single yeast cell indicated that no significant irreversible photo-damage occurred, but these fluctuations suggest changes in the trapping conditions or biochemical changes associated with the cellular machinery in the cell. The technique is particularly suitable for applications where dynamics of spectra are of interest.
Multiwavelength Transmission (MWT) UV-Vis-NIR spectroscopy, an effective technique often underutilized for the characterization of processes involving particulates, such as protein aggregation, is systematically explored using bovine serum albumin and a set of NIST-traceable particle size (PS) standards having certified particle diameters over the nominal size range of 30 to 100 nm. The PS standards are used as surrogates for protein aggregates and other contaminants such as oils and microbubbles. Therefore, the standards can be used to quantitatively modify the optical properties of protein solutions and thus observe the effect of the presence of aggregates and other particulates on their wavelength-dependent transmission spectra. The experimental results demonstrate that the changes induced in the optical density spectra of proteins due to the presence of PS particles are detectable and consistent with the expectations set by light scattering theory. It is demonstrated that the size and relative concentrations of the particle populations present in the protein samples can be quantified. Because of the considerable dynamic range of MWT UV-Vis-NIR spectroscopy for particle analysis and its real-time measurement capabilities, this type of spectroscopy can be effectively used for the characterization of protein aggregates and for the continuous real-time monitoring of aggregation processes and for the identification and quantification of contaminants in protein-based products.
A methodology based on dispersive micro solid-phase extraction (DMSPE) using multiwalled carbon nanotubes (MWCNTs) as solid sorbent prior to measurement with energy-dispersive X-ray fluorescence (EDXRF) spectrometry is proposed. The procedure consists of chelating of nickel, cobalt, copper, and lead ions with ammonium pyrrolidinedi-thiocarbamate (APDC) and posterior adsorption of metal chelates on MWCNTs (1 mg) dispersed in the aqueous samples (100 mL). DMSPE promotes immediate interaction between the metal chelates and MWCNTs and shortens time of sample preparation in comparison with classical solid-phase extraction. After microextraction process, MWCNTs are collected onto filter and directly measured by EDXRF. With this technique, the direct quantification of metal species held in solid materials is possible and, therefore, the elution step can be avoided. The effects of various experimental parameters such as pH of the solution, amounts of MWCNTs and APDC, sample volume, and time of stirring were investigated. With the best analytical conditions (1 mg of MWCNTs, 2 mg of APDC, 100 mL sample volume, pH = 7, and 5 min time of stirring), Co(II), Ni(II), Cu(II), and Pb(II) can be simultaneously determined with very good recoveries (101%, 98%, 96%, 99%, respectively) and detection limits (0.43, 0.11, 0.46, 0.15 ng mL−1, respectively). The method was applied in determination of trace metal ions in tap water and wastewater samples.
The native fluorescence (FL) spectra of muscle foods (meat) stored at 4 °C (refrigerated) and 25 °C (at room temperature) were measured with the selected excitation wavelength of 340 nm as a function of storage time to detect the meat spoilage status. The contributions of the principal biochemical components to the FL spectra were extracted using Multivariate Curve Resolution with Alternating Least-Squares (MCR-ALS). The change of the reduced nicotinamide adenine dinucleotide (NADH) content was found from the measured FL spectra and the MCR-ALS analysis, which reflects the microbial spoilage of muscle foods involved in the metabolic processes. This study presents the possibility that the change of relative content of NADH determined by native FL spectroscopy may be used as a “fingerprint” or criterion for monitoring the spoilage status of muscle foods.