Previous studies have compared various technology-based devices, such as ultrasonography (USG), near-infrared (NIR), and transilluminator (TI), with standard care (SC) to facilitate peripheral intravenous cannulation (PIVC) in pediatric patients. This study aims to investigate the efficacy of these interventions on the first-attempt success rate (FASR) of PIVC in pediatric patients with difficult intravenous access (DIVA) using network meta-analysis (NMA).
We conducted a comprehensive literature search in databases to identify randomized clinical trials comparing the effects of different devices on the FASR of PIVC from inception until August 2023. Pooled relative risks with 95% credible intervals were estimated using pairwise and network meta-analysis with random effects. To rank the efficacy of devices, we calculated the probabilities of the surface under the cumulative ranking curve (SUCRA).
A total of 18 studies were included in the final analysis. The results of pairwise meta-analysis showed that the use of devices increased the FASR for PIVC by 13% (RR: 1.13, 95% CI: [0.98, 1.30]) compared to SC. The ranking of interventions based on efficacy from highest to lowest was as follows: USG (SUCRA: 1), NIR (SUCRA: 0.6), SC (SUCRA: 0.3), and TI (SUCRA: 0.1), with a very low confidence estimate.
Based on our findings, the prioritization of device usage to increase the FASR of PIVC in pediatric patients with DIVA is as follows: USG, NIR, SC, and TI, respectively. However, due to inconsistencies in the network, existence of an overall high risk of bias in the included studies, and very low confidence estimate, further clinical trials are required.
Central venous access devices are essential for the management of critically ill patients, but they are potentially associated with many complications, which may occur during or after insertion. Many evidence-based documents—consensus and guidelines—suggest practical recommendations for reducing catheter-related complications, but they have some limitations. Some documents are not focused on critically ill patients; other documents address only some special strategies, such as the use of ultrasound; other documents are biased by obsolete concepts, inappropriate terminology, and lack of considerations for new technologies and new methods. Thus, the Italian Group of Venous Access Devices (GAVeCeLT) has decided to offer an updated compendium of the main strategies—old and new—that should be adopted for minimizing catheter-related complications in the adult critically ill patient. The project has been planned as a consensus, rather than a guideline, since many issues in this field are relatively recent, and few high-quality randomized clinical studies are currently available, particularly in the area of indications and choice of the device. Panelists were chosen between the Italian vascular access experts who had published papers on peer-reviewed journals about this topic in the last few years. The consensus process was carried out according to the RAND/University of California at Los Angeles (UCLA) Appropriateness Methodology, a modification of the Delphi method, that is, a structured process for collecting knowledge from groups of experts through a series of questionnaires. The final document has been structured as statements which answer to four major sets of questions regarding central venous access in the critically ill: (1) before insertion (seven questions), (2) during insertion (eight questions), (3) after insertion (three questions), and (4) at removal (three questions).
The proper location of the tip of a central venous access device plays a crucial role in minimizing the risks potentially associated with its use. Recent guidelines strongly recommend preferring real-time, intra-procedural methods of tip location since they are more accurate, more reliable and more cost-effective than post-procedural methods. Intracavitary electrocardiography and real time ultrasound can both be applied in the neonatal setting, but they offer different advantages or disadvantages depending on the type of central venous access device. Reviewing the evidence currently available about the use of these two methods in neonates, in terms of applicability, feasibility and accuracy, it can be concluded that (a) real time ultrasound is the only acceptable methodology for tip navigation for any central venous access device in neonates, (b) intracavitary electrocardiography is the preferred method of tip location for central catheters inserted by ultrasound-guided cannulation of the internal jugular vein or the brachiocephalic vein, and (c) real time ultrasound is the preferred method of tip location for umbilical venous catheters, epicutaneo-cava catheters, and central catheters inserted by ultrasound-guided cannulation of the common femoral vein.
Central venous obstructions that impedes catheter placement or results in catheter dysfunction is a significant problem for haemodialysis patients. Recanalization can be performed with an intent to restore central venous access, improve outflow from arteriovenous fistula or to relieve symptomatic venous obstructions. Sharp recanalization encompasses various interventional techniques using a sharp instrument to puncture through or bypass around a venous obstruction. In this paper we outline our experience performing CT guided sharp recanalization and review alternative sharp recanalization techniques that are specifically used to restore haemodialysis access in patients with thoracic central venous obstruction.
Catheter-related bloodstream infections are among the most critical issues associated with central venous catheters used for dialysis treatment. To reduce the incidence of this life-threatening complication, various strategies have been developed. Among these, Hub Devices have been introduced in clinical practice to prevent microbial growth at the hub of the catheter.
A review was conducted to assess the effectiveness of Hub Devices in reducing bloodstream infections in central venous catheters for dialysis, compared to solid caps. The review analyzed existing literature from three bibliographic databases (PubMed, Embase, and CINAHL) to provide evidence-based recommendations for clinical practice.
After a thorough review of the available data, it was found that out of the 873 records screened, only six trials met the inclusion criteria. Albeit the number of patients observed in these trials was more than 25,000, due to the differences in the mechanism of action of different Hub Devices and the lack of a standardized criterion to identify and measure the outcomes, it is difficult to draw a firm conclusion. It is worth noting, however, that in five out of six trials examined, the Hub Devices exhibited a protective effect when compared to solid caps.
The use of Hub Devices appears to be associated with a reduction in catheter-related bloodstream infections in the central venous catheter dialysis population. However, the Hub Devices show interesting results that should be investigated with further well-designed prospective studies.
This systematic review and meta-analysis aimed to assess the association of neutrophil-to-lymphocyte ratio (NLR) with an elevated risk of vascular access failure in end-stage renal disease (ESRD) patients undergoing hemodialysis. A comprehensive database search of MEDLINE (via PubMed), Scopus, and Cochrane Central was performed. Studies reporting the values of NLR in both functional and non-functional AVF groups in ESRD patients were selected. Quality assessment was performed using the Modified Newcastle-Ottawa scale for observational studies. Meta-analysis was performed using an inverse variance random effects model. Seven observational studies met the inclusion criteria, including 1313 participants with 554 cases and 759 controls. Pooled results showed significantly high NLR levels in patients with non-functional arteriovenous fistula (AVF) compared to functional AVF (SMD = 1.19, 95% CI = 0.74–1.65,
A more accurate descriptive and clinically useful diagnosis based upon pathophysiology for what is commonly referred to as venous outflow stenosis is inflow-outflow imbalance. In these cases, the total outflow capacity of the AV access is inadequate to handle the inflow volume (Qa) without an increase in pressure. The relative inadequacy of the access outflow capacity in comparison to Qa results in increased outflow resistance and a proportional increase in intraluminal pressure. The clinical indicators associated with venous stenosis are the resulting manifestations of this imbalance. The point at which this occurs is dependent upon variations in these two parameters—Qa and outflow resistance. The variations in these two parameters are considerable and reciprocal. Excessive Qa results in or can lead to an entire list of serious problems that adversely affect patient morbidity and mortality. Most studies dealing with AV access Qa reduction have been for the treatment of an existing condition rather than its prevention; however, prevention of disease rather than waiting for its development is an important tenet of medical practice. The resulting clinical picture of inflow-outflow imbalance is taken as an indication for corrective treatment. In the past, in most cases this has meant angioplasty to open the outflow if it is reduced; however, this clinical picture may be associated with an excessive Qa and angioplasty in these cases creates the risk for a further increase in Qa. It is the authors’ opinion that access flow measurements should be a part of the evaluation of these cases prior to planning treatment. Using this information, a bimodal approach to primary treatment should be adopted involving either angioplasty for cases with a low or normal Qa or flow reduction in cases with an elevated Qa.
Management of central venous catheters (CVC) is a frequent procedure in intensive care units (ICUs) and the risk of bloodstream infections (CLABSI) is found to be high. The literature provides healthcare professionals with guidelines to prevent the risk of CLABSI infections. The aim of this study was to observe the knowledge, attitudes, and practices of ICU nurses on the prevention of CLABSI.
A multicenter cross-sectional study was conducted between March 2023 and September 2023; the research was carried out among six ICUs in Bari both on the web and in paper mode. The survey consisted of multiple-choice questions structured in two sections: demographic sample data and the 2017 Esposito MR questionnaire, drawn up based on the 2011 guidelines of the Centers for Disease Control and Prevention, consisting of four dimensions: knowledge, attitudes, practices, information.
121 nurses (57.1%) participated in the study. 72% were unfamiliar with the guidelines, especially nurses aged 41–50 years (RR = 1.88; CI = 0.78–4.51;
We observed a reduced knowledge of the guidelines for the prevention of CLABSI despite the attitudes and practices of the nurses being satisfactory. In addition to implementing training, strategies for disseminating guidelines should be adopted.
The internal jugular vein (IJV) is one of the most used sites for central venous access. Some authors revealed the association of a higher deformation rate of the IJV wall with posterior wall penetration, which may cause a hemorrhagic complication. A newly developed thin-tip needle (three-dimensional (3D) needle) reduced the deformation rate in an ex vivo study. Therefore, we conducted a clinical study to investigate its efficacy in reducing vessel deformity during IJV puncture.
This study retrospectively enrolled 80 adult patients who received central venous port (CVP) implantation via the IJV from April 1, 2022, to November 10, 2023, in our institution. Traditional needle-and-catheter was used for ultrasound (US)-guided IJV puncture (usual group) for the former 40 patients before July 18, 2023. Afterward, the 3D needle was used for the latter 40 patients (3D needle group). US images were stored and analyzed to calculate the deformation rate.
The deformation rate was 58.6% (13.2–100) for the usual needle and 41.8% (10.6–100) for the 3D needle (
The deformation rate of the IJV wall was smaller in the 3D needle group than in the usual needle group. The use of a 3D needle would be safer when puncturing the IJV.
Central venous catheterization may be required in patients with amyotrophic lateral sclerosis (ALS) for parenteral nutrition, antibiotic treatment, or blood sampling. Different venous access devices can be taken into consideration—centrally inserted central catheters (CICC), peripherally inserted central catheters (PICC), and femorally inserted central catheters (FICCs)—depending on the clinical conditions of the patients. Regardless of the type of access, the presence of paraplegia or tetraplegia is commonly considered a risk factor for catheter-related thrombosis (CRT).
This retrospective study analyzes the rate of CRT and other non-infectious complications associated with central venous access in a cohort of 115 patients with paraplegia or tetraplegia, most of them affected by ALS (
In a period of 34 months, from January 2021 to October 2023, we inserted 75 FICCs, 29 CICCs, and 11 PICCs. PICCs were inserted only in patients with preserved motility of the upper limbs. All devices were inserted by trained operators adopting appropriate insertion bundles. We had no immediate or early complication. Though antithrombotic prophylaxis was adopted only in 61.7% of patients, we had no symptomatic CRT. Other non-infectious complications were infrequent (4 out of 115 patients).
These results suggest (a) that the presence of paraplegia or tetraplegia is not necessarily associated with an increased risk of CRT, (b) that the adoption of well-designed insertion bundles plays a key role in minimizing non-infectious complications, and (c) that the insertion of FICCs by direct cannulation of the superficial femoral vein at mid-thigh in paraplegic/tetraplegic patients may have the same advantages which have been described in the general population.
Short peripheral catheters (SPCs) are affected by a high complication rate that leads to catheter failure. Currently, the Visual Infusion Phlebitis score (VIP) is the most used tool to verify the presence of inflammatory complications (phlebitis and thrombophlebitis). However, ultrasound signs (US) may be an attractive alternative.
This study aims to evaluate the sensitivity and specificity of US and VIP score = 1 in identifying and recognizing early signs of SPC failure. The time to positivity for US and VIP scores was assessed as a secondary outcome.
An observational prospective study was conducted. In each patient, US (subcutaneous edema; fibroblastic sleeve; thrombophlebitis) and VIP of the exit site were performed every 24 h until 96 h after insertion. Compared to catheter failure, Sensitivity, Specificity, and Predictive values in both US and VIP were calculated.
Two hundred patients were enrolled. The presence of ultrasonic pattern suggestive of edema at 72 h (
An ultrasound inflammatory pattern is correlated with SPC failure. An ultrasound protocol—requiring minimal training—is more effective than VIP in recognizing early signs of device failure.
To compare relative risk (RR) of central line-associated bloodstream infection (CLABSI) between hospitals using Clave needleless connector technologies (NCT) and comparator hospitals using non-Clave NCT. And, to estimate avoided CLABSIs, mortality, and cost savings.
Needleless connectors, while protective against needlestick injury, have long been implicated as a potential risk for CLABSI. Significant RR reduction of CLABSI among the many NCT has not been clinically demonstrated.
The U.S. Healthcare-Associated Infections database was accessed for CLABSI data for calendar year 2019 via the Centers for Medicare and Medicaid Services website. This dataset was merged with the Clave NCT manufacturer’s 2019 database to identify hospitals purchasing Clave NCT (MicroClave™, NanoClave™, Clave Neutron™, Clave™, Microclave™ Clear) and non-Clave NCT comparator hospitals. Sub-analysis of Clave NCT hospitals included: (1) Clave NCT mixed-use and (2) Clave high-volume use hospitals. The standardized infection ratio (SIR) was generated to estimate CLABSI RR after adjusting for intern/resident-to-bed-ratio (IRB), care location, and hospital demographics. Using the RR, avoided CLABSIs, mortality, and cost savings were calculated.
A total of 2987 eligible hospitals (1288 Clave NCT, 1699 non-Clave NCT) with 17,452,575 central line-days were evaluated. All three Clave NCT hospital groups showed a statistically significant reduction in RR compared to the non-Clave NCT hospitals. The RR in Clave NCT hospitals was 0.93, a 7% decrease in CLABSI risk (
The use of the Clave NCT, in and of itself, is an effective risk reduction strategy for CLABSI prevention, reduced mortality, and substantial cost savings.
The possibility of creating an arteriovenous fistula (AVF) depends on the existence of an arterial–venous network that is in good condition, defined by the size and elasticity of the blood vessels. The knowledge, attitudes, and practices (KAP) toward vascular protection play a crucial role in preserving the vascular network for patients with end-stage renal disease (ESRD), it is observed that there is a significant lack of tools to measure these variables. Thus, the aim of this study is to develop and validate a scale to assess KAP regarding vascular protection anticipatory to the creation of an arteriovenous fistula (the KAP-VPAC-AVF Scale).
Initial item development was guided by a literature review and clinical experience, after which the items were improved and perfected through the Delphi process. The content of the scale was judged by an expert panel for content validity. In a convenience sample of 551 patients with ESRD, exploratory factor analysis (EFA) and confirmatory factor analysis (CFA) were conducted to examine the instrument’s factor structure.
The KAP-VPAC-AVF Scale encompasses 11 items distributed over three factors: knowledge, attitude, and practice, demonstrated excellent internal consistency (Cronbach’s alpha = 0.917) and construct validity, as confirmed by CFA with satisfactory fit indices (χ2/
The KAP-VPAC-AVF Scale is a scientific and effective assessment tool that can evaluate the KAP of ESRD patients regarding measures to preserve the vascular network.
To quantify the rates and identify risk factors for the complications of central venous access devices (CVADs) removal in children.
Retrospective (2018–2023) review of children undergoing CVADs removal at a single institution. Data are reported as frequency, percentages and median. Logistic regression analysis was used to identify risk factors associated with difficult removal. Receiver Operating Characteristic Curve (ROC) analysis was conducted to identify the age cut-off and positive likelihood ratio (+LH) for the indwelling time associated with complicated removal.
We identified 208 CVAD removals with a median age of 7.2 (0.2–18.4) years including 116 (55.8%) males. The median CVAD placement duration was 1.26 years (0.4–5.7) years. Indications for insertion included acute lymphoblastic leukaemia (ALL; 78/208, 37.5%), lymphomas (31/208, 14.9%), other malignancies (58/208, 27.9%). Removal indications included completion of treatment (144/208, 69.2%), infection (22/208, 10.6%), malfunction (7/208, 3.4%) and other reasons (35/208, 16.8%). There were 20 (9.6%) complications characterised by difficulty removing the CVAD. Complicated removals were more likely to occur in children with ALL as the primary diagnosis (
In our experience, almost 10% of CVAD removals in children result in complications. These findings are associated with an indwelling time >2 years; strategies to prevent complicated removals should be considered in children requiring long-term central venous access.
Catheter related thrombosis is a common complication of tunnelled central venous catheter (TCVC) usage. There are concerns that TCVC removal could dislodge a thrombus to cause pulmonary thromboembolism (PE). The incidence of PE following TCVC removal is unclear and so the aim of this study was to investigate the incidence of PE and whether it is high enough to warrant screening with ultrasound with a view to systemic anticoagulation prior to TCVC removal.
1102 consecutive TCVC removals without ultrasound and systemic anticoagulation were included in this retrospective study. Data were extracted from electronic health records. Measures to identify PE events included: deaths, computed tomography pulmonary angiogram (CT-PA), isotope lung perfusion scans and D-dimers blood tests within 7 days of removal.
Of the 1102 TCVC removals, the mean age of patients was 56.9 years and 57.3% were male. The primary renal diagnosis for 24.5% of patients was diabetic nephropathy. There were seven deaths following removal, none of which had PE as a contributing cause on review of their clinical history and death certificates. Five CT-PAs and one isotope lung perfusion scan were carried out in the 7 days after TCVC removal and none had a positive finding of PE. Three patient had D-dimers measured in blood within 7 days and none of these patients were subsequently diagnosed with PE.
There was no evidence of fatal or non-fatal PE’s occurring in the 7 days following TCVC removal. This would support the practice of removing TCVCs without the need for ultrasound screening and without a period of systemic anticoagulation.
Cephalic arch stenosis (CAS) is often recurrent, resistant to treatment and the intervention outcome is not well validated so far. We purposed to assess the clinical outcomes of CAS treatment in patients with hemodialysis access.
Electronic bibliographic sources were searched up to December 4 2023 to identify studies reported outcome after treating CAS. Direct and indirect evidence was combined to compare odds ratios (OR) and surfaces under the cumulative ranking curves across the different treatment modalities through meta-analysis and network meta-analyses (NMA). This systematic review was conducted in accordance with the PRISMA-P. The review is registered in PROSPERO (CRD42022296513).
Four randomized controlled trials (RCTs) and 15 non-RCTs were included in the analysis. The study population differed in fistula type, restenosis or thrombosis, and significant heterogeneity was observed among the publications. The risk of bias was low to serious. Meta-analysis found no significant difference between DCB and PTA in primary patency at 6 and 12 months (OR 1.16 and 0.60, respectively; low certainty of evidence). Favorable result with STG compared to stent or PTA at 3, 6, and 12 month was observed (OR 4.28, 5.13, and 13.12, and 4.28, 5.13, 13.12, respectively; low certainty of evidence). Regarding primary patency, the treatment rankings, from highest to lowest, were STG (92.7%), transposition (76.0%), stent (67.5%), PTA (64.5%), and DCB (46.3%) at 12 months.
Despite data limitations, the low-quality evidence suggests that STG may merit consideration as a primary treatment option when all alternatives are applicable, given their potential for better primary patency and higher treatment ranking.
Totally implanted venous access device are widely used for long-term chemotherapy in cancer patients. Previous studies have only focused on the analysis of complications associated with infusion port implantation, ignoring the causes of unsuccessful infusion port implantation. The purpose of this study was to investigate the association between body mass index (BMI) and the success rate of transaxillary intravenous port implantation in breast cancer patients.
To review 361 breast cancer patients who underwent intravenous port implantation from January 2021 to September 2021. Baseline data, and surgical data were collected from the patients, and the success rate of puncture of the axillary vein was recorded. The logistic regression analysis and smoothed curve fitting were used to assess the relationship between BMI and the success rate of axillary venipuncture. In addition, subgroup analyses were performed to explore potential interactions.
Under ultrasound guidance, 67.3% of patients (243/361) had an infusion port implanted by axillary vein puncture. There was a roughly linear relationship between BMI and the success rate of axillary venipuncture. In the multiple regression equation, BMI was significantly and negatively associated with the success rate of axillary venipuncture (OR = 0.83; 95% CI = 0.77–0.89;
The higher the patient’s BMI, the higher the chance of difficult axillary venipuncture or failed cannulation.
Thrombosis of the vascular access in patients with end-stage renal disease requiring hemodialysis are common and require timely interventional procedures to restore patency. The aim of the current study was to identify factors having a significant effect on patency rates after access thrombosis. Our hypothesis was the length of time between the initial clotting of the access and the subsequent percutaneous declotting impacts the patency rates of the vascular access.
In this retrospective cohort study, patients with a clotted arteriovenous access between Jan 1, 2011, and Jan 1, 2016, were included. Demographics, access history, and associated details of the access procedure were reviewed from the electronic medical record. Statistical analysis was done using
There were 883 percutaneous declotting procedures reviewed. About 351 procedures were performed in patients with an AVF and 532 with an AVG. The mean time from thrombosis to declotting was 1.71 ± 2.29 days. The overall median primary patency for both AVF and AVG was 43 days with no difference in patency between patients with AVF (39 days) versus AVG (42 days;
Time from thrombosis to declotting did not affect patency rates however once there was a thrombotic event, recurrent thrombosis requiring intervention was common with patency significantly decreased. Future prospective studies to validate our results and study pathogenic mechanisms of recurrent thrombosis are warranted.
A multitude of challenges arises from the growing utilisation of peripherally inserted central catheters (PICCs), including the ability to provide timely, effective and safe insertion, which must be ensured and prioritised in patient care. A nurse-led model of care has become more prevalent as PICCs become extensively needed due to their applications. However, despite their widespread use, such intervention is yet in its inception in Saudi Arabia, and thereby, evaluating the outcomes of this service is of utmost importance to support patient safety initiatives and quality of care.
This research aims to assess the effectiveness of a nurse-led PICC placement service.
A quantitative retrospective cohort design was used. The sample of this study was 333 random subsets of records on PICC insertion for adult patients between 1st April 2019 and 31st March 2023 in a tertiary medical facility in Riyadh, Saudi Arabia.
A nurse-led PICC service demonstrated an overall successful placement of 330 cases (99.1%), out of which 323 PICCs (97%) were successfully inserted under intra-cavitary electrocardiogram (IC-ECG) guidance, while 7 PICCs (2.1%) were successfully inserted with fluoroscopy. The overall complication rate was 2.35 occurrences per 1000 CL days, whereas the complication rate within the first 10 days after PICC insertion was 0.42 per 1000 CL days.
A nurse-led model for PICC insertion has remarkably high success rates and low rates of complication, highlighting the pivotal role of a specialised PICC team. This service boasted a commendable track record of achieving a high rate of success in its implementation, implying that a nurse-led PICC service operates effectively to improve the patient experience by delivering timely and high-quality healthcare service.
Balloon-assisted maturation (BAM) is a well-established technique for maturation of inadequate arteriovenous fistulas (AVF). The objective of this study was to evaluate outcomes of initial BAM using large-diameter angioplasty balloons.
Charts of patients who underwent BAM between 2018 and 2021 at a single academic institution were reviewed. AVF maturation rate was the primary outcome. Secondary outcomes included procedural complications, re-intervention rates, post-procedure vein diameter, and time to catheter-free hemodialysis (HD). Outcomes of patients that underwent initial BAM with ⩾7 mm diameter balloons (Group I) were compared to those of patients that had initial BAM with <7 mm balloons (Group II).
Group I (
Our study demonstrates that the ability to utilize large angioplasty balloons during initial BAM is associated with higher rates of AVF maturation with fewer re-interventions and shorter time to catheter-free dialysis. AVFs that can tolerate this procedure often have more favorable baseline characteristics.
The distal radial artery presents a particular challenge for puncture and catheterization due to its diminutive size, tortuous path, and tendency to spasm, increasing the risk of procedural failure and injury. Ultrasound guidance improves success rates and reduces risk in radial artery catheterization. This study evaluates the efficacy and safety of a refined dynamic needle tip positioning technique for distal radial artery access.
One hundred twelve patients were randomized to either the modified dynamic needle tip positioning technique (MDNTP) or palpation guidance groups (palpation group), each with 56 participants. The primary outcomes were the success rate of the initial puncture and overall puncture success rate, while secondary outcomes included procedural time and complications such as puncture site hematoma and radial artery occlusion within 24 h.
The MDNTP group exhibited superior initial puncture success (71.43% vs 46.43%,
The MDNTP technique boosts the success of distal radial artery puncture and catheterization, reducing the risk of complications associated with the procedure.
Venodilation is crucial in enhancing the success rate of peripheral intravenous cannulation. Flow-mediated dilation (FMD) is a vasodilatory response initiated by temporary ischemia followed by reperfusion. This crossover study aimed to test the hypothesis that FMD induces dilation of the peripheral veins of the forearm.
Fifteen healthy volunteers underwent the FMD and control conditions in a randomized order. FMD involved a 5-min occlusion of blood flow in the brachial artery, followed by reperfusion, achieved by inflating and deflating a cuff placed on the upper arm. The control condition involved participants remaining at rest. The primary outcome measure was a change in the cross-sectional area of the cephalic vein post-intervention. The secondary outcomes included changes in venous diameter and perfusion index (PI).
FMD significantly increased the cross-sectional area of the cephalic vein compared with the control condition (relative change to baseline: 37.7% (31.4) vs 2.2% (11.7)), with a mean difference of 35.4% (95% confidence interval (CI): 16.4–54.5,
FMD application induced dilation of the cephalic vein of the forearm. The findings suggest that FMD is an effective technique for dilating the venous area and potentially improving the success rate of peripheral intravenous cannulation.
To assess the effectiveness and safety of the InThrill Thrombectomy System in treating thrombosed arteriovenous fistulas (AVFs) and grafts (AVGs) via mechanical thrombectomy.
Institutional database was retrospectively searched to identify all thrombectomy procedures performed using the study device at our hospital for thrombosis of AVFs or AVGs. Inclusion criteria encompassed patients aged 18 and above who underwent AV access thrombectomy using the study device. Intraprocedural metrics, including procedure time, device time, blood loss, and adjunctive procedures were collected. Technical success was defined as restoration of flow combined with <30% residual diameter stenosis of the treated vascular segment. Clinical success was defined as the resumption of normal hemodialysis for a minimum of at least one session following intervention. Through 3-month follow-up, patency, and adverse events were evaluated.
A total of 20 thrombectomies were performed on 2 AVFs and 18 AVGs in 13 patients. Median procedure and device times were 45 and 10 min, respectively. Balloon angioplasty was performed in all cases with additional stenting in 40% (8/20) of cases to address stenosis following thrombus removal. No other mechanical thrombectomy devices were utilized. Intraprocedural thrombolytics were not administered in any case. Average blood loss was 10 mL. The technical success and clinical success rates were 100% (20/20) and 95% (19/20), respectively. There were no intraoperative adverse events. One patient developed a post-operative minor hematoma, and one patient developed a post-operative pseudoaneurysm at the access site. The primary patency rate was 77% (10/13) at 1 month. Both assisted primary and secondary patency rates were 100% at 1 and 3 months.
These preliminary results suggest that the InThrill Thrombectomy System is rapid, safe, and effective for thrombolytic-free treatment of AV access thrombosis in hemodialysis patients.
Resistant chronic total occlusion (CTO) lesions present an ongoing challenge for conventional endovascular interventions to restore functional hemodialysis (HD) access. This study endeavors to present a novel endovascular approach utilizing ultrasound (USG)-guided percutaneous sharp recanalization to cross the resistant occlusions and evaluates its effectiveness.
This is a multi-center retrospective review of consecutive patients received USG guided sharp recanalization for the treatment of resistant CTO lesions of their HD access between 1st January 2019 and 31st July 2023. Data encompassing patient demographics, access and lesion characteristics, procedural specifics, associated complications, immediate clinical outcomes, and outcomes during follow-up were collected. The procedural technical and clinical success, Kaplan-Meier estimated target lesion (TLPP), access circuit primary patency (ACPP), and index access secondary patency (SP) were reported.
During the study period, 22 patients underwent USG-guided sharp recanalization procedures in the three participating centers with median follow-up of 14.5 months. Both the technical and clinical success were 100%. Only two patients experienced minor complications of localized hematoma over the access, with no instances of major complication. Kaplan-Meier estimated TLPP and ACPP at 3-, 6-, and 12 months were 90.9%, 68.2%, 56.8%, and 90.9%, 63.6%, 52.1% respectively. The SP rates were 100%, 95.5%, and 84.1% at 3-, 6-, and 12 months respectively.
USG guided percutaneous sharp recanalization is an effective and safe endovascular approach to treat resistant CTO lesions of dysfunctional HD access.
Iatrogenic femoral artery pseudoaneurysm (FAP) is a complication following femoral artery puncture, with an incidence rate of 0.2%–5.5% post-cardiac catheterization procedures. Management typically involves observation or interventional treatments such as ultrasound-guided compression (UGC) or ultrasound-guided thrombin injections. This study compares the efficacy and safety of ultrasound-guided autologous blood clot injection (UGCI) with C-clamp vascular closure device-assisted UGC in treating FAP.
Conducted at a high-volume training and research center, this prospective study enrolled patients with iatrogenic FAP post-femoral artery puncture. Patients were randomized into two treatments: UGC with a C-clamp device or UGCI. Primary endpoints were thrombosis induction within 24 h, average procedure time, and length of hospital stay (LOS).
The study included 105 patients with 51 undergoing UGCI and 54 undergoing UGC. UGCI achieved a primary success rate of 96% versus 63% for UGC. The mean procedure duration for UGCI was significantly shorter (22 min) compared with UGC (49 min,
UGCI demonstrated to be a safe, efficient, and faster alternative for treating iatrogenic FAPs with a higher success rate, reduced LOS, and similar low complication rates compared to UGC. This study suggests that UGCI could be considered a preferred method for the management of FAP post-femoral artery catheterization.
Many cases of chronic thoracic central vein occlusion (CVO) fail to recanalize using the standard conventional guidewire technique. This study aims to present the outcomes of sharp recanalization with a transseptal needle in chronic thoracic CVO.
This retrospective study involved 22 hemodialysis patients who developed clinical signs and symptoms of CVO, had unsuccessful conventional endovascular treatment using guidewire, and underwent sharp recanalization with a transseptal needle from January 2018 to December 2021. Demographic information of patients, technical success rate, and complications were kept. Post-intervention primary patency rate was examined using survival regression.
Thirteen men and nine women were enrolled with a median age of 50 years (range: 30–83 years). The most common site of thoracic CVO was the right brachiocephalic vein (21 patients). The average length of occlusion was 2.5 cm (range: 1–4.4 cm). Technical success rate was 90.9% (20 patients). Major complications occurred in three instances, including severe hemothorax and pulmonary edema. The median post-intervention primary patency between balloon angioplasty alone and primary stenting was 2.1 and 8.0 months (
Sharp recanalization with a transseptal needle is successful in chronic thoracic CVO cases that fail with conventional recanalization. Primary stenting in this CVO lesion shows a greater primary patency compared to balloon angioplasty alone.
The preferred techniques for peritoneal dialysis catheterization are uncertain. Catheter implantation with formation of an inferiorly-directed tunnel and exit site is widely recommended to reduce the risk of infective complications. We aimed to compare percutaneous peritoneal dialysis catheter insertion using an upwardly-directed tract to catheter insertion using a downwardly-directed tract.
A retrospective cohort study was performed on consecutive peritoneal dialysis catheterizations over a 10-year period at a single centre. Participants were classified into two groups: catheter insertion with an upward tunnel and exit site versus insertion with a downward tunnel and exit site. The primary outcome was peritoneal dialysis catheter survival.
There were 247 peritoneal dialysis catheters inserted during the study period. The median catheter survival was 18 months, with no difference between the two groups (
In this study, percutaneous peritoneal dialysis catheter insertion with an upward tunnel and exit site demonstrated similar catheter survival to insertion with a downward tunnel and exit site and was not associated with increased infections.
No research has been conducted to compare long-axis in-plane and short-axis out-of-plane techniques for ultrasound-guided posterior tibial artery cannulation in adults. This study compared these two procedures for cannulating the posterior tibial artery.
This prospective randomized trial included 236 adult patients undergoing general anesthesia who required arterial cannulation. The posterior tibial artery was cannulated using either the long-axis in-plane technique (group LAIP) or the short-axis out-of-plane method (group SAOP) with an ultrasound machine. First-attempt cannulation success, the number of cannulation attempts required to achieve successful cannulation, ultrasound localization time, cannulation time, and perioperative complications in these two groups were analyzed.
The LAIP group demonstrated a significantly higher first-attempt success rate (40.7% vs 18.6%,
The LAIP group demonstrated higher first-attempt and overall success rates compared to the SAOP group for ultrasound-guided posterior tibial artery (PTA) cannulation in adult patients.
In the pediatric setting, the procurement of vascular access can be particularly difficult. Surgical venolysis was the first technique described but, in recent years, the literature has shown that ultrasound-guided implantation has fewer complications. The principal aim of this paper is to state how after a structured training to place ultrasound-guided central lines, venolysis was definitively abandoned in our hospital. We also analyzed the impact of training on the duration of procedures. Finally, the number of procedures performed per operator to maintain the quality standard achieved.
In this observational retrospective study, we analyzed data from 2013 to 2020 of 1497 pediatric and neonatal central venous access placements in a single center during a training path.
Venolysis performed by the pediatric surgeons was used in 11% of total placements, the most in the smallest patients (76.1%, <1 year of age). With the implementation of training, this invasive technique became obsolete to the point where it was no longer practiced (24.6% of vascular placement in 2013 to 0% in 2020). In the placement performed by the pediatric anesthesiologists, time progressively decreased from 51.5 min in 2013 to 29.4 min in 2022. From the analysis of the number of procedures performed by pediatric anesthesiologists, the first consultant involved performed averaging 48 procedures per year, while the other consultants had an overall average of 16.7–25 placements per year.
Echo-guided vascular cannulation was found to be safe, reliable, and reproducible in pediatric patients and neonates and permits to deletion definitively venolysis. Well-structured training is essential and should be standardized in the future.
To compare primary patency after angioplasty with drug-coated balloon (DCB)-Passeo-18Lux, BIOTRONIK versus uncoated balloon in dysfunctional peripheral vascular access (PVA) for hemodialysis.
A total of 133 patients from four hospitals were randomized to receive DCB or plain old balloon angioplasty (POBA) after satisfactory treatment (residual stenosis <30%) with high pressure balloon (HPB). The primary endpoint was clinical patency of PVA 2 years after angioplasty. Secondary endpoints included the relationship between the location of stenosis and patency and also, other covariates. Mortality at 2 years was compared between both groups.
Patency measured in days after angioplasty was higher in fistulae dilated with DCB than HPB. Kaplan-Meier survival curves showed the next percent of success (free time restenosis) after DCB versus POBA at 6 months—77.1% versus 58.2% (160.41–143.72 days until restenosis), 12 months—51.4% versus 44.3% (274.1–237.23), 18 months—38.6% versus 38% (350.74–305.18), and 24 months—37.1% versus 30.4% (419.04–369.1). At 6 months, this difference was statistically significant (
DCB angioplasty resulted in superior target lesion primary patency (TLPP)-free survival at 6 months of follow-up. No significant improvements in TLPP-free survival long term were observed. Mortality observed at 1 and 2 years was similar in DCB and POBA: there was no significant difference, and a safety study demonstrated no difference between the two groups (complications and mortality): DCB is safe to use in stenosis treatment in patients who are PVA carriers.
Level Ia, therapeutic study, RCT. EBM ratings will be based on a scale of 1–5.
Patients in the urology ward often require peripheral intravenous catheters for cancer chemotherapy, antibiotics to treat urinary tract infections, surgery, and other treatments. Moreover, as the elderly population within urology has a high incidence of cancer, many patients also have fragile vasculature. Proper intravenous catheter insertion and management are crucial in such cases. However, no observational studies have revealed specific practices and patient outcomes related to intravenous catheter insertion and management in urology wards. This study aimed to clarify the actual situation of peripheral intravenous catheter placements in patients hospitalized in a general urology ward and investigate the risk factors for patient outcomes such as difficult intravenous access (DIVA) and catheter failure (CF).
This was a prospective observational study. Medical record data were collected, and the actual catheter placement situation was described. A multivariate logistic regression analysis was performed to investigate the risk factors for DIVA and CF.
This study analyzed 180 catheters in 99 patients. The median age of the group was 70 years. The prevalence of DIVA and CF were 9.9% and 35.2%, respectively. A history of intravenous chemotherapy for cancer was positively associated with both DIVA and CF.
This study’s results demonstrate the crucial need for careful insertion and management of intravenous catheters in patients admitted to urology wards. These findings can help identify patients at high risk of DIVA and CF, while hospitalized in the urology ward.
Short peripheral catheter (SPC)-associated complications occur frequently in hospitalised neonates. Few studies have reported the use of SPC care bundles in resource-limited neonatal units.
To evaluate the impact of a SPC care bundle on SPC associated complications (infiltration, dislodgement, phlebitis) and catheter dwell time.
We conducted a quasi-experimental study comparing neonatal SPC complications during a 2-month baseline and a 2-month intervention period, where a SPC care bundle was introduced including hand hygiene, insertion site antisepsis, nurse assistance during cannulation, IV insertion carts and IV securement dressings.
A total of 459 SPC days were observed in 223 neonates: 111 pre-intervention and 112 post-intervention (after SPC bundle implementation). Most neonates were preterm (208, 93.3%) with very or extremely low birth weight (133, 59.6%). SPC care bundle compliance was 43.8% for five bundle elements and 83.9% for four bundle elements. Most SPCs had unplanned removal within 48 h of insertion owing to infiltration or dislodgement (89/111 pre-intervention (80.2%) vs 90/112 post-intervention (80.4%); 0.974). No phlebitis was documented. The mean SPC dwell time was unchanged following bundle implementation (32.9 vs 34.2 h;
Infiltration and dislodgement occurred frequently necessitating replacement of four of every five SPCs. Despite moderate compliance with the SPC care bundle, the high rates of unplanned SPC removal and short duration of catheter dwell time were unchanged.
The SPC care bundle did not improve catheter dwell time; further research is needed to identify strategies to reduce unplanned SPC removal and extend catheter dwell time in hospitalised neonates.
Angioplasty balloon rupture is a rare complication during percutaneous transluminal angioplasty (PTA). Conventional approach to retrieve circumferentially ruptured balloons is open surgery. This study examined the feasibility of a novel approach which can remove ruptured balloon during PTA in vascular access.
This retrospective study analyzed 35 patients of a total 6465 patients that underwent ultrasound-guided PTA with a circumferential balloon rupture from February 2016 and August 2023. The patients underwent surgery (Group I,
The total incidence of circumferential balloon rupture was 0.5% in our center. Balloon retrieval was successful in both groups with no complications except one case had an infection in the surgical wound. Kaplan–Meier curve analysis showed that the post-intervention primary patency rates of the two methods were not significantly different (
The feasibility of the novel technique for retrieval of circumferential ruptured balloons during ultrasound-guided PTA is validated. The technique enables less invasive retrieval and continuation of PTA.
This study aimed to determine the impact of virtual reality glasses and ball squeezing methods on reducing pain and anxiety in adult patients undergoing short peripheral cannula placement.
The pretest-posttest parallel group randomized controlled experimental study was conducted in a university hospital with 111 patients. Patients were randomly assigned to one of three groups: the VR group (
There was no statistically significant difference between the groups in terms of sociodemographic characteristics (
The study found that virtual reality glasses and ball squeezing were effective distraction methods to reduce pain and anxiety in patients undergoing short peripheral cannula placement.
Arterial catheterisation is a common procedure used to manage critically ill patients. The radial artery, both for its favourable anatomical position and the presence of ulnar collateral circulation, is the most used. While there is a consensus for a catheter/vein ratio of ⩽33% for venous catheterisation, there are no strong indications for arterial catheterisation. Some authors have hypothesised that a catheter/artery ratio of less than 45% is advisable. This study aimed to explore the relationship between residual flow in the Radial Artery, the catheter/artery ratio, and ulnar compensation.
This retrospective observational study included patients with radial artery catheters in general wards and intensive care units of a tertiary hospital in Italy. Residual flow in the radial artery was calculated by measuring the Peak Systolic Velocity and diameter of the artery at the midpoint of the arm. The reverse Barbeau test was used to assess the residual perfusion. The sample was stratified and analysed to the catheter/artery ratio being greater or less than 33% and 45% and to the score obtained during the reverse Barbeau test.
The data obtained showed a significant statistical correlation between residual flow, catheter/artery ratio, and the reverse Barbeau test (
Adhering to the current guidelines, especially using ultrasound to ensure a catheter/artery ratio of at least 45%, can help maintain preserved perfusion through the cannulated radial artery. Ulnar compensation appears to be crucial for maintaining good tissue perfusion and should always be evaluated before catheterisation. Therefore, further studies are warranted.
The Renal Expert in Vascular Access (REVAC) is one of the four modules of the Nephrology Partnership for Advancing Technology in Healthcare (N-PATH) project, the first European-wide advanced training course in diagnostics and interventional nephrology, funded by Erasmus+ Knowledge Alliance, a European Commission program. The N-PATH primary goal was to train 40 young European nephrologists in both theoretical knowledge and practical skills related to interventional nephrology. The REVAC module focused on the crucial aspects of vascular access (VA) care in nephrology practice, as a complementary training path to the actual residency program. The aim was to provide nephrology fellows with comprehensive knowledge and skills related to VA management. The methodology was based on face-to-face meetings and online learning, modern facilities, experienced tutors, cutting edge simulators, augmented reality tools by means of a multidisciplinary international faculty and hands-on-courses. A feedback survey reported the experience of fellows who attended the REVAC module, confirming the positive impact on their ongoing nephrology training. We are confident that this project will revitalize their nephrology careers and will help training the next generation of nephrologists; they will be able to manage VA needs with the help of multi-disciplinary teams to safely optimize the care of hemodialysis patients.
To describe an alternative arteriovenous fistula (AVF) model involving anastomosis of the common carotid artery (CCA) with the posterior facial vein (PFV).
Twenty-two male Sprague-Dawley rats (age 6–8 weeks) were used to establish the AVF model involving end-to-side anastomosis of PFV and CCA. The peak velocity of the CCA and the diameter of the outflow vein were recorded at 7, 14, and 42 days after the operation using Doppler ultrasound. Pathological examination of the intimal lesions was performed at 14 and 42 days after operation.
One rat died within 24 h after surgery related to anesthesia. The patency rates at days 7, 14, and 42 were 85.7%, 81%, and 81%, respectively. The diameter of the carotid artery in rats is approximately 0.8 mm. The diameter of the outflow vein was increased by 1.7-fold and 2.2-fold at 7 days (1.1 ± 0.118 mm) and 14 days (1.4 ± 0.073 mm). At 42 days (1.96 ± 0.101 mm) after operation, the diameter was 3-fold greater compared to the unoperated control rat. The peak systolic flow velocity of the carotid artery at 7 days (593 ± 17.36 mm/s) and 14 days (767 ± 13.64 mm/s) after surgery was significantly greater compared to the control rat (314 ± 15.13 mm/s). The rate of increase was fastest at 7 days and leveled off from 14 to 42 days (875 ± 26 mm/s) after surgery. At 14 days, the intima area showed a nearly 50-fold increase (230 ± 9.93 μm2 × 103) compared to control (area 5 ± 0.37 μm2 × 103). Comparing 6 weeks with 2 weeks (280 ± 10.54 μm2 × 103) after surgery, the intima area increased 1.2 times.
The CCA-PFV fistula in rats is a viable alternative AVF model.
To investigate the feasibility, methods and effects of interventional ultrasound in nitinol stent implantation to treat early restenosis after percutaneous transluminal angioplasty (PTA) in autogenous arteriovenous fistula (AVF).
From April 2018 to December 2021, 69 patients with early restenosis of AVF received ultrasound-guided nitinol stent implantation (UNSI) and were followed-up. Imaging features of the stent and procedure by ultrasound were observed. The technical success rate, clinical success rate and incidence of complications were recorded and counted. Target lesion primary patency (TLPP), access circuit primary patency (ACPP) and access circuit secondary patency (ACSP) were estimated.
Ultrasonography can show the structure of the stent and guide the stenting process clearly. Both the technical and clinical success rates were 100%. Thirty-one patients had in-stent restenosis (ISR), which was treated by plain balloon (PB) PTA or drug coated balloon (DCB) PTA. The TLPP at 3, 6, 12 and 24 months were 100.0%, 94.2%, 63.4% and 39.6%, respectively. The ACPP at 3, 6, 12 and 24 months were 98.6%, 91.6%, 60.2% and 35.2%, respectively. The ACSP at 3, 6, 12 and 24 months were 98.6%, 98.6%, 95.6% and 93.8%, respectively. The TLPP of ISR after DCB PTA at 3, 6 and 12 months were 100.0%, 100.0% and 93.6%, respectively.
This pilot study indicates ultrasonography can accurately guide nitinol stent implantation in AVF and this technique is a feasible and minimally invasive treatment for early restenosis after PTA with good short- and medium-term patency. DCB PTA may be used to deal with the ISR and is a way to prolong the patency of nitinol stent.
Intracavitary electrocardiography (IC-ECG) is a non-invasive method for intraprocedural tip location during central venous catheterization. Over the last 20 years, the IC-ECG method has been thoroughly investigated and many studies have confirmed its wide applicability and feasibility, as well as its great accuracy and safety in different populations of patients and in different types of central venous access devices (CVADs). This retrospective study presents a two-center experience with tip location of central venous catheters using IC-ECG, by means of a new wireless portable device. Tip location was performed during 983 insertions of CVADs at bedside, using this new device. Clinical conditions with limited or no applicability of IC-ECG were excluded. The feasibility of IC-ECG, as performed using the novel device, was 92.2%. This wireless device may play an important role in central venous catheterization at bedside, since it is pocket-sized, particularly easy to use, and easy to sanify after use.
Central venous catheters are a frequently used vascular access for hemodialysis. Fibrin sheath formation is a common complication and is associated with catheter malfunction. Although fibrin sheath angioplasty with catheter exchange is a frequently employed procedure, it can be associated with mechanical complications. An important technical step in this procedure is progression of the guide-wire into the inferior vena cava. Focal alveolar hemorrhage is a very rare complication of this procedure. We report a case of a 70-year old patient on dual antiplatelet therapy who underwent fibrin sheath angioplasty with guide-wire catheter exchange and experienced focal alveolar hemorrhage presenting as hemoptysis and acute type 1 respiratory failure. Progression of the guide-wire into the pulmonary circulation and antithrombotic therapy played a significant role in the development of this complication. This report aims to call attention to a poorly described and potentially serious yet avoidable complication of fibrin sheath angioplasty with guide-wire catheter exchange.
A 25-year-old female patient with chronic glomerulonephritis, initiated on haemodialysis presented with high-grade fever, a dysfunctional catheter, low oxygen saturation and unstable blood pressure. Upon evaluation, the patient was febrile with elevated white blood cell counts. She was intubated, started on inotropes and transferred to the intensive care unit. Chest radiography showed that the tunnelled internal jugular dialysis catheter had migrated to the inferior vena cava. Echocardiography and transoesophageal echocardiography showed severe heart dysfunction with a large thrombus attached to the catheter, indicating catheter-related atrial thrombus (CRAT). CT pulmonary angiography revealed blockage of the segmental pulmonary arteries, suggesting pulmonary embolism. Blood and tracheal cultures revealed Methicillin-resistant Staphylococcus aureus (MRSA). The patient was administered appropriate antibiotics and anticoagulants and underwent surgical removal of the thrombus and the catheter. This case demonstrates the risks associated with improper placement of dialysis catheters and highlights the brief management of CRAT.
The total occlusion of radial artery is a contraindication for reintervention and further usage. In this study, we report successful revascularization with creation of radiocephalic fistula from post-procedural chronically-occluded radial artery. The completely occluded radial artery was recanalized through ultrasound guided balloon angioplasty. A traditional radiocephalic fistula was created subsequently by using the recanalized radial artery for hemodialysis therapy. Though the fistula was failed at the 6 weeks caused by the juxta anastomotic stenosis, the further ultrasound guided percutaneous transluminal angioplasty restored the blood, and the hemodialysis therapy lasts for more than 1 year so far. It’s feasible to create radiocephalic fistula based on the recanalized radial artery and maintain long-term hemodialysis therapy.
The construction and utilization of dependable vascular access are essential for hemodialysis. Despite its importance, complications with vascular access are common, significantly impacting patient morbidity and mortality. This report presents a novel approach to treating chronic total occlusion (CTO) in hemodialysis vascular access using the “wire kissing technique” an “externalization and pull-through technique.” An 82-year-old woman on hemodialysis had a thrombotic obstruction in her cephalic vein, which conventional methods failed to address. The wire kissing technique allowed the meeting of antegrade and retrograde wires within the CTO lesion, stabilizing the wire and facilitating balloon passage. The externalization and pull-through technique further enabled the balloon to cross the rigid CTO lesion, successfully completing percutaneous transluminal angioplasty (PTA). Post-procedure ultrasonography showed significant improvements in flow volume and resistance index. These techniques, commonly used in coronary and femoral arteries, have not been previously reported for dialysis vascular access. This case highlights a novel and effective solution for overcoming technical difficulties in crossing CTO lesions, potentially improving outcomes in vascular access for hemodialysis patients.
Mirror people have difficulty with PICC placement due to inversion of organs. Intracavitary electrocardiography (IC-ECG) guided peripherally inserted central catheter (PICC) tip location technique has been widely applied in clinical practice.
Herein, we admitted a 59-year-old man diagnosed with esophageal cancer (EC). Chest X-ray and computed tomography (CT) revealed that the patient was with a mirror-image dextrocardia and situs inversus totalis: the heart and stomach located in the right side of the body, whereas the liver located in the left side. Echocardiography suggested that the apex of the heart pointed toward the right, while the left and right chambers were inverted. The relationship of the heart chambers, structure, and function were normal: left ventricular ejection fraction was 0.67, left atrial diameter was 31 mm, and heart output was 4.7 L/min. Surface ECG showed typical features of a dextrocardia: P-wave inverted on lead I. Amplitude of the R-wave and S-wave decreased gradually on lead chest from V1 to V5. Compared with the normal ECG image, the waves completely exchanged on lead II and III, so as on aVR and aVL.
Column of saline technique can assist operator estimate the tip position in real-time according to P-wave changes. When the height of P-wave reaches to its highest, it means that the tip of catheter has advanced to the target position of cavo-atrial junction (CAJ).
Patient was inserted catheter and no adverse events were reported.
Measuring the predicted length of catheter is still an indispensible procedure to help precisely adjusting the tip position in IC-ECG guided PICC. Our work provides both supplement for clinical data to facilitate further research and better understanding of special types of PICC to clinicians.